![Ross RCS-8120 User Manual Download Page 12](http://html1.mh-extra.com/html/ross/rcs-8120/rcs-8120_user-manual_1488966012.webp)
Module Installation
The RCS-8120 were designed to be mounted in the MRP-8120 1RU mounting panel (which can hold
up to 5 modules), or mounted in desk with the DCA-8120 in desk mounting adapter. Blank cover
plates are available for unused positions on the MRP-8120.
Rack-mount Installation
Use the following steps to install the module in a RossGear MRP-8120 chassis unit:
1. Remove the 4 corner hex nuts from the cover plate bolts.
2. Remove the 2 hex nuts that attach the U bracket to the module cover plate.
3. Install the cover plate on the MRP-8120 (or DCA-8120) with the 4 corner hex nuts.
4. Attach the switch unit to the module cover plate with the 2 hex nuts at the U bracket.
5. Repeat this procedure for each module and any blank slot cover plates you wish to
install to the MRP-8120 chassis. All five of the module slots on the chassis should
be occupied with modules or blank plates.
6. Install the MRP-8120 chassis in the rack.
4 Corner
Hex Nuts
2 U-Bracket
Hex Nuts
Figure 2. Rack Mount Installation Details
2-2
•
Installation and Setup
RCS-8120 User Manual (Iss. 01A)