Ross MC1-MK Quick Start Manual Download Page 4

4

Technical Support: (+1) 613-652-4886

After Hours Emergency: (+1) 613-349-0006

E-mail: [email protected] 

TCP/IP Connection via a Comtrol DeviceMaster

The Digital Alert Systems Dasdec-2 connects to the MC1-MK over TCP/IP using a Comtrol 

DeviceMaster. 

You will need a DB-9 female to DB-9 female null modem cable. Ross Video does not supply this 

cable.

1.

Connect the Digital Alert Systems Dasdec-2 to the Comtrol DeviceMaster via the RS-232 serial port 

on the Dasdec-2 and an available serial port on the Comtrol DeviceMaster. 

2.

Connect the MC1-MK to the same network as the Comtrol DeviceMaster.

EAS Audio Voice Over Connection

This section outlines how to connect the Digital Alert Systems Dasdec-2 to the MC1-MK for an EAS 

audio voice over setup.
You will need to:

1.

Connect the 

GPO 

(

RELAY

) port on the Digital Alert Systems Dasdec-2 to the 

GPI 1

 port on the 

MC1-MK rear module. Refer to the 

MC1-MK Installation Guide

 for GPIO pinout information.

Ross Video does not supply this cable.

2.

Ensure that the Dasdec-2 

GPO 

(

RELAY

) port is configured for 

PTT Relay

 programming. 

3.

Configure the 

GPO 

(

RELAY

) port on the Dasdec-2 for 

EAS Audio Playout

MC1-MK Audio Connections

When connecting the MC1-MK-MK to the Digital Alert Systems Dasdec-2, you will also need one of the 

following openGear cards for audio:
• AES audio — an MUX-8258-A is required
• Analog audio — an MUX-8258-4C or MUX-8258-8C is required 
Both methods are outlined in this section.

For More Information on...

• Dasdec-2 audio pinouts, refer to its user documentation.

AES Audio

The Digital Alert Systems Dasdec-2, when equipped with AES audio, provides AES outputs on a DB9 

connector. A breakout cable is required to adapt these AES output for the MUX-8258-A. 

Ross Video does not supply these cables.

1.

Connect the breakout cable from the 

AES AUDIO

 port on the Dasdec-2 to the MUX-8258-A as 

shown in 

Figure 2

.

2.

Ensure that Dasdec-2 

Audio Output

 is set to 

48000

 samples/second.

Analog Audio

The Dasdec-2 connects to the MUX-8258-C via two audio ports. You will need two XLR cables. Each 

cable must include an XLR-3F 3-pin female connector (to connect to the Dasdec-2) on one end, and 

one WECO™ 3-pin connector on the other (to connect to the MUX-8258-C rear module). Refer to the 

MUX-8258 User Manual

 for rear module pinout details.

Ross Video does not supply these cables.

Summary of Contents for MC1-MK

Page 1: ...the MC1 MK 1 Communications connection Serial or TCP IP via Comtrol DeviceMaster to provide EAS crawl text 2 EAS Voice Over connection using an GPI to the MC1 MK 3 Analog or AES audio connection to pr...

Page 2: ...ort Proceed to connect the MC1 MK to the Digital Alert Systems Dasdec 2 Connecting the Dasdec 2 to the MC1 MK There are two cabling options for establishing communications between the MC1 MK and the D...

Page 3: ...s are specified on the Digital Alert Systems Dasdec 2 Set the SERIAL port on the Dasdec 2 to Sage Generic CG Refer to Table 5 for additional serial settings For More Information on configuring your Da...

Page 4: ...ay programming 3 Configure the GPO RELAY port on the Dasdec 2 for EAS Audio Playout MC1 MK Audio Connections When connecting the MC1 MK MK to the Digital Alert Systems Dasdec 2 you will also need one...

Page 5: ...the Dasdec 2 audio to two or more channels as required b Disable the Audio Groups and mute the channels that are not used 5 Select the AES or Analog Inputs tab 6 Configure the Delay and Gain as requir...

Page 6: ...le for EAS audio voice over support To enable EAS audio voice over 1 Select the GPI Tally tab 2 Locate the row for the MC1 MK GPI port you connected to the GPO RELAY port on the Dasdec 2 3 Select GPI...

Page 7: ...you want to customize The following will occur once you select a category button For normal EAS operation set the Preview to OFF The EAS Setup tab settings display the stored values for the selected c...

Page 8: ...8 Technical Support 1 613 652 4886 After Hours Emergency 1 613 349 0006 E mail techsupport rossvideo com...