Ross DFR-8104A User Manual Download Page 10

1–2 • Introduction

DFR-8104A(-C) User Manual (Iss. 03)

Overview

The DFR-8104A(-C) Digital Products Frame accommodates up to four Ross 8000 series 
Distribution Products or four Leitch 6800 series video products. For high power consumption 
requirements, the DFR-8104A can be field upgraded with the CFM-8104A Cooling Fan Module, 
which is mounted in a slot between the power supply and module slot number four. Alternatively, 
the DFR-8104A-C comes direct from the factory with the cooling fan option already installed. 
The DFR-8104A(-C) design offers several key features such as; heavy-duty door hinges, durable 
powder-coat paint finish, and a specially designed top cover to enable frame stacking in high 
density environments. 

The DFR-8104A(-C) carries forward the heritage of our past digital frames by featuring our 
unique Master Reference Input, which accepts one external analog color black signal that is 
distributed to all modules. The frame also employs rugged aluminum construction, which 
provides superb heat dissipation, as well as the use of the highest quality connectors throughout 
the product.

The PS-8102 universal power supply is a power factor corrected supply that will accommodate 
all world standards (100-240 volts) with up to 80 Watts of module power. Of special note is that 
the PS-8102 has the ability to sustain a 100ms input voltage loss, or glitch, while maintaining a 
full power output. This is of great importance in areas where incoming power may not be clean. 

Features

The following features make the DFR-8104A(-C) one of the finest digital products frames on the 
market today:

• Each frame accommodates four modules in 1 RU
• Heavy duty door hinges
• Durable powder-coat paint finish
• Aluminum construction for increased heat dissipation and weight reduction
• Master Reference Input feeds all module slots
• Power Switch is accessible from front of the rack frame
• Universal Power Supply (PS-8102) for all world standards (100-240 volts)
• PS-8102 sustains a 100ms incoming power glitch while maintaining full output power
• Power factor corrected supply with power fail detection circuit
• PowerLock cord retainer mechanism guards against accidental power loss
• Optional Cooling Fan Module for increased ventilation
• Fan Fail and Error Indicator LED's on front of the frame (available with optional Cooling 

Fan Module)

• Optional Extender Board Module for servicing
• Optional Cable Support Bracket
• Optional Frame Support Brackets 
• 5-year transferable warranty
• Also accepts Leitch 6800 series video products

Note

 — It is recommended, for long-term reliability and increased product life span, 

that total dissipation of all modules installed in a DFR-8104A(-C) 1RU frame should 
not exceed 16 Watts total without the use of the Cooling Fan Module. Refer to the 
section “

Ventilation and Cooling

” on page 2-4 for details.

Summary of Contents for DFR-8104A

Page 1: ...Ross Video Limited DFR 8104A C Digital Products Frame and Power Supply PS 8102 User Manual...

Page 2: ...02 446 7 834 886 7 914 332 This product is protected by the following Canadian Patents 2039277 1237518 1127289 Other patents pending Notice The material in this manual is furnished for informational u...

Page 3: ...s intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product Failure to heed this information may present a ris...

Page 4: ...a norme NMB 003 du Canada EUROPE This equipment is in compliance with the essential requirements and other relevant provisions of CE Directive 93 68 EEC INTERNATIONAL This equipment has been tested to...

Page 5: ...ral resources Ross Video encourages you to use the appropriate take back systems These systems will reuse or recycle most of the materials from your end of life equipment in an environmentally friendl...

Page 6: ...O Box 880 Ogdensburg New York USA 13669 0880 General Business Office 1 613 652 4886 Fax 1 613 652 4425 Technical Support 1 613 652 4886 After Hours Emergency 1 613 349 0006 E mail Technical Support t...

Page 7: ...verview 2 3 Power Supply PS 8102 and Power Cable 2 3 Fault Reporting 2 4 Improving Performance 2 4 Ventilation and Cooling 2 4 Cabling for the DFR 8104A C 2 5 Cabling Overview 2 5 Optional Field Upgra...

Page 8: ...ii Contents DFR 8104A C User Manual Iss 03...

Page 9: ...products backed by Ross Video s experience in engineering and design expertise since 1974 You will be pleased at how easily your new DFR 8104A C fits into your overall working environment Equally ple...

Page 10: ...ability to sustain a 100ms input voltage loss or glitch while maintaining a full power output This is of great importance in areas where incoming power may not be clean Features The following features...

Page 11: ...efers to the frame with the CFM 8104A Cooling Fan Module DFR 8104A C refers to all versions of the frame unless otherwise noted Operator and User refer to the person who uses DFR 8104A C Board and Car...

Page 12: ...1 4 Introduction DFR 8104A C User Manual Iss 03...

Page 13: ...allation 2 1 Installation In This Chapter This chapter provides instructions for installing the DFR 8104A C and cabling details The following topics are discussed Before You Begin Installing the DFR 8...

Page 14: ...ved from the shipping container and ensure that all items are included If any items are missing or damaged contact your sales representative or Ross Video directly ESD Susceptibility Static discharge...

Page 15: ...he modules in the frame This is an essential feature for applications such as program feeds live event feeds or wherever a robust signal system is required The PS 8102 is a power factor corrected supp...

Page 16: ...e an empty 1RU panel space above and below the frame for improved heat dissipation For information on the power dissipation of RossGear cards contact your Ross Video sales representative or visit our...

Page 17: ...o an opt isolator circuit in the frame For example in the case of the SRA 8001A Serial Auto Reclocking Amplifier if the input signal is lost or low the INPUT STATUS Red LED will be lit If the FAULT RE...

Page 18: ...d across the back plane to all modules Typically analog black video is used Some cards which need an external reference can use this master reference signal in place of taking the signal from one of t...

Page 19: ...User Manual Iss 03 Optional Field Upgrade Kits 3 1 Optional Field Upgrade Kits In This Chapter This chapter contains the following sections CFM 8104A Cooling Fan Overview FSB 7110 Rear Support Bars a...

Page 20: ...lable as a field upgrade kit Figure 3 1 CFM 8104A Cooling Fan Module Installing the CFM 8104A Use the following procedure to install the CFM 8104A in a DFR 8104A 1 Turn off the power supply and observ...

Page 21: ...can be attached to the DFR 8104A C in six possible positions Figure 3 2 Figure 3 2 FSB 7110 Rear Support Bars and Brackets Use the following procedure to install the FSB 7110 for the DFR 8104A C 1 Cho...

Page 22: ...3 4 Optional Field Upgrade Kits DFR 8104A C User Manual Iss 03...

Page 23: ...User Manual Iss 03 Specifications 4 1 Specifications In This Chapter This chapter provides the technical specification information for the DFR 8104A C The following topics are discussed Technical Spe...

Page 24: ...details on higher load applications requiring greater heat dissipation Table 4 1 DFR 8104A C Technical Specifications Category Parameter Specification Power Supply Input Voltage 100 240VAC 50 60Hz Inp...

Page 25: ...DFR 8104A C User Manual Iss 03 Service Information 5 1 Service Information In This Chapter This chapter contains the following sections Troubleshooting Checklist Warranty and Repair Policy...

Page 26: ...me and any associated peripheral equipment for signs of trouble 2 Power Check Check the power indicator LED on the distribution frame front panel for the presence of power If the power LED is not illu...

Page 27: ...ear DFR 8104A C User Manual provides all pertinent information for the safe installation and operation of your RossGear Product Ross Video policy dictates that all repairs to the RossGear DFR 8104A C...

Page 28: ...on Related products and full product lines On line catalog News Testimonials Ross Part Number 8104ADR 004 03 PHONE General Business Office and Technical Support 613 652 4886 After Hours Emergency 613...

Reviews: