Warranty and Repair Policy

 

The RossGear CMA-8011A is warranted to be free of any defect with respect to performance, quality, 
reliability, and workmanship for a period of FIVE (5) years from the date of shipment from our 
factory. In the event that your RossGear CMA-8011A proves to be defective in any way during this 
warranty period, Ross Video Limited reserves the right to repair or replace this piece of equipment 
with a unit of equal or superior performance characteristics. 

Should you find that this RossGear CMA-8011A has failed after your warranty period has expired, we 
will repair your defective product for as long as suitable replacement components are available. You, 
the owner, will bear any labor and/or component costs incurred in the repair or refurbishment of said 
equipment beyond the FIVE (5) year warranty period. 

In no event shall Ross Video Limited be liable for direct, indirect, special, incidental, or consequential 
damages (including loss of profits) incurred by the use of this product. Implied warranties are 
expressly limited to the duration of this warranty. 

This RossGear CMA-8011A Component Monitoring Amplifier User Manual of our Analog Video 
Products line provides all pertinent information for the safe installation and operation of your 
RossGear Product. Ross Video policy dictates that all repairs to the RossGear CMA-8011A are to be 
conducted only by an authorized Ross Video Limited factory representative. Therefore, any 
unauthorized attempt to repair this product, by anyone other than an authorized Ross Video Limited 
factory representative, will automatically void the warranty. Please contact Ross Video Technical 
Support for more information. 

In Case of Problems 

Should any problem arise with your RossGear CMA-8011A, please contact the Ross Video Technical 
Support Department. (Contact information is supplied at the end of this publication.) 

A Return Material Authorization number (RMA) will be issued to you, as well as specific shipping 
instructions, should you wish our factory to repair your RossGear CMA-8011A. A temporary 
replacement module, if required, will be made available at a nominal charge. Any shipping costs 
incurred, will be the responsibility of you, the customer. All products shipped to you from Ross Video 
Limited, will be shipped collect. 

The Ross Video Technical Support department will continue to provide advice on any product 
manufactured by Ross Video Limited, beyond the warranty period without charge, for the life of this 
equipment.

5-2  

  Service Information 

CMA-8011A User Manual (Iss.05) 

Summary of Contents for CMA-8011A

Page 1: ...Ross Video Limited CMA 8011A Component Monitoring Amplifier User Manual Ross Part Number 8011ADR 004 Issue 05...

Page 2: ...yrighted software is prohibited Notice The material in this manual is furnished for informational use only It is subject to change without notice and should not be construed as a commitment by Ross Vi...

Page 3: ...quipment damage or a situation which could place the equipment in a non compliant operating state ESD Susceptibility This symbol is used to alert the user that an electrical or electronic device or as...

Page 4: ...th Canadian ICES 003 Cet appareil numerique de classe A est conforme la norme NMB 003 du Canada EUROPE This equipment is in compliance with the essential requirements and other relevant provisions of...

Page 5: ...ral resources Ross Video encourages you to use the appropriate take back systems These systems will reuse or recycle most of the materials from your end of life equipment in an environmentally friendl...

Page 6: ......

Page 7: ...ion Setting 2 3 Board Installation 2 3 BNC Labels 2 3 Cable Connections 2 4 LEDs 2 4 SMPTE 269M Fault Reporting 3 1 In This Chapter 3 1 Overview 3 1 Jumper Setup 3 2 Frame Connections 3 2 Details 3 2...

Page 8: ...ii Contents CMA 8011A User Manual Iss 05...

Page 9: ...Ross Video s experience in engineering and design expertise since 1974 You will be pleased at how easily your new CMA 8011A fits into your overall working environment Equally pleasing is the product q...

Page 10: ...A 8011A also outputs four reclocked SDI streams The SDI input has an exceptionally good cable equalizer that will give error free performance with up to 305 meters 1000 ft of Belden 8281 cable Several...

Page 11: ...ss Video 8000 series digital products frames and Leitch 6800 series frames 5 year transferable warranty Documentation Terms The following terms are used throughout this guide Frame refers to the DFR 8...

Page 12: ...1 4 Introduction CMA 8011A User Manual Iss 05...

Page 13: ...ESD Susceptibility Static discharge can cause serious damage to sensitive semiconductor devices Avoid handling circuit boards in high static environments such as carpeted areas and when wearing synth...

Page 14: ...OMA OFF Used to output luminance only for the best picture on a monochrome monitor NORMAL Blanks all vertical interval information signals 20 line blanking 3 V BLANK SHORT Passes all vertical interval...

Page 15: ...ignal and using a scope set the EQUALIZATION adjustment for correct chroma level at the destination Board Installation Use the following steps to install the CMA 8011A cards in a RossGear DFR 8104A or...

Page 16: ...Composite Out 2 Composite Out 4 SDI Out 1 SDI Out 3 Composite Out 1 Composite Out 3 Figure 3 Cabling Designations for RossGear 8000 Series Frames It is not necessary to terminate unused analog or dig...

Page 17: ...may still be restored correctly but the circuits will be working close to the limit of their capability and reliability cannot be assured Red This indicator identifies a problem either with the input...

Page 18: ...2 6 Installation and Setup CMA 8011A User Manual Iss 05...

Page 19: ...TE 269M fault reporting The card connects by means of an internal interface circuit to an auxiliary telco connector on RossGear 8000 series frames When the frame connection is interfaced with a custom...

Page 20: ...PTE 269M Fault Reporting connection on RossGear 8000 series frames is provided by the auxiliary telco connector AUX A for interfacing with a customer designed alarm system AUX A Connector for SMPTE 26...

Page 21: ...Specifications In This Chapter This chapter contains the CMA 8011A Technical Specifications table CMA 8011A User Manual Iss 05 Specifications 4 1...

Page 22: ...20 80 850ps Typical Overshoot 8 SDI Output Delay SDI Input to SDI Output 13ns Number of Outputs 4 Standards NTSC or PAL composite video Output Impdeance 75 Output Return Loss 35dB to 6MHz Output Isol...

Page 23: ...wer Check Check the power indicator LED on the distribution frame front panel for the presence of power If the power LED is not illuminated verify that the power cable is connected to a power source a...

Page 24: ...oducts line provides all pertinent information for the safe installation and operation of your RossGear Product Ross Video policy dictates that all repairs to the RossGear CMA 8011A are to be conducte...

Page 25: ...04A C Digital Products Frame with Cooling Fan Module and Power Supply PS 8102 1RU holds 4 modules includes 1 power supply DFR 8110A Digital Products Frame and Power Supply PS 8102 2RU holds 10 modules...

Page 26: ...Notes 6 2 Ordering Information CMA 8011A User Manual Iss 01...

Page 27: ...Notes CMA 8011A User Manual Iss 05 Ordering Information 6 3...

Page 28: ...fter hours Emergency 613 652 4886 ext 333 PHONE Fax 613 652 4425 General Information solutions rossvideo com E MAIL Technical Support techsupport rossvideo com Ross Video Limited 8 John Street Iroquoi...

Reviews: