ROSITEK RMP2 User Manual And Troubleshooting Download Page 3

PAGE 2

Rositek Technologies 

www.rositek.com

© 2021 Rositek

All rights reserved

Email: [email protected]

USER GUIDE AND TROUBLESHOOTING -- RMP2

INTRODUCTION

                              

READ BEFORE  

OPERATING

MACHINERY

Thank you for purchasing this Rositek product.

Before using this device, please read these instructions and Safety    

Precautions carefully.

After reading and familiarizing yourself with the device, store the manual in a 

safe place for future references.

RMP2 is Rositek 2-ton manual heat press with a customized leverage system with an extra-long 

handle. It’s portable, small, and effortless; Solid frame, non-rusting & non-breaking.

The following precautions are provided to prevent harm or injury to yourself and others.Please make 

sure to thoroughly read, understand, and follow these precautions before using. After reading and 

familiarizing yourself with the equipment, store the manual in a safe place for future references.

• Use this product only as described in this manual.

• Keep the equipment out of the reach of children at all times.

• Unplug the heat press from the electrical outlet and let it cool down  

COMPLETELY before cleaning, performing maintenance, or repair.

• DO NOT operate the product after the appliance malfunctions or is dropped or 

damaged in any way.

• Clean the plates with isopropyl alcohol and wipe them dry with a clean cloth. 

Ensure both plates are completely dry before use.

• DO NOT leave any cords near a heat source.

• DO NOT handle a power plug or other components of the press with wet hands.

• DO NOT connect too many power plugs to the same power outlet.

• Remove dust around the plug and power cord with a clean dry cloth.

• DO NOT disassemble the press or make any modifications to the equipment 

without professional instructions.

WARNING: Follow the warnings below.

SAFETY PRECAUTIONS

The units are intended for LEGAL use only, in accordance with your  

federal,  state, and local laws, ordinances, and regulations.

DISCLAIMER

Summary of Contents for RMP2

Page 1: ...CONTACT Rositek Technologies E mail support rositek com 2021 Rositek www rositek com All rights reserved MANUAL HEAT PRESS MODEL No RMP2 USER GUIDE AND TROUBLESHOOTING ...

Page 2: ...tructions Item Checklist PAGE 4 6 GETTING FAMILIAR RMP2 Features and Controls Front RMP2 Features and Controls Back RMP2 Product Size PAGE 7 10 OPERATING INSTRUCTIONS Preparing Press Starting Press PID Control Instruction How to Set Back to Default Settings Setting Control Panel 1 Method Workbench Operation 2 Method Ground Operation Turning Off Press Cleaning Press Plates PAGE 11 PAGE 11 TECHNICAL...

Page 3: ...the manual in a safe place for future references Use this product only as described in this manual Keep the equipment out of the reach of children at all times Unplug the heat press from the electrical outlet and let it cool down COMPLETELY before cleaning performing maintenance or repair DO NOT operate the product after the appliance malfunctions or is dropped or damaged in any way Clean the plat...

Page 4: ... electrical cord or any other way without proper grounding DO NOT exceed the rated capacity Always turn the machine OFF and unplug it when done using UNPACKING UNPACKING INSTRUCTIONS 1 Place the box on a flat surface Open the box and remove the user guide and all parts that came with the device 2 Examine the device after unpacking for any damage If found one take a picture and contact Rositek at s...

Page 5: ...OOTING RMP2 GETTING FAMILIAR RMP2 FEATURES AND CONTROLS FRONT Top Platen Bottom Platen Pluggable Single PID Temperature Controller Machine Base ON OFF Switch Bamboo Insulators Customized Lever System Made of Blackened Steel Extra long Pressure Handle Pressure Adjusting Knob Clockwise to increase the pressure Frame Pedal Armrest ...

Page 6: ...ologies www rositek com 2021 Rositek All rights reserved Email support rositek com RMP2 FEATURES AND CONTROLS BACK Power Cord Socket Thermocouple Heating Rods GETTING FAMILIAR continued USER GUIDE AND TROUBLESHOOTING RMP2 ...

Page 7: ...sitek Technologies www rositek com 2021 Rositek All rights reserved Email support rositek com USER GUIDE AND TROUBLESHOOTING RMP2 GETTING FAMILIAR continued RMP2 PRODUCT SIZE Left view size mm Front View Size mm ...

Page 8: ...o an electrical outlet OPERATING INSTRUCTIONS STARTING PRESS 1 Flip the ON OFF switch to turn the press on The PID temp controller and the power switch both become lit PID CONTROLLER INSTRUCTION FOR RMP2 PV Process Value Red color SV Set Value Green color UP Key DOWN Key SHIFT Key Press this key to shift left and right position SET Parameter Setting Press this key to shift digit of parameter value...

Page 9: ...hanging the internal parameters it will cause a lot of problems Once a problem occurs after the modification please set the default setting back as below steps 1 Hold the SET key over 5 seconds to activate the controller 2 Press the SET again to switch parameters 3 Press the SHIFT key to switch between the hundreds tens and ones place 4 To set the parameter with the key of down or up 5 Please ensu...

Page 10: ...o shift left and right position 2 Press UP and DOWN keys to set the desired temperature 3 Press SET key to record all control panel s setting The platens start heating and PV is now displayed on the screen Tips 1 We recommend loading 3 5 5g material at a time for a better result 2 The parchment paper is a must during the extraction but filter bags and prepress mold is optional 2x4 5 pressing bags ...

Page 11: ...e is installed and locked into place reinstall the power cord 7 Turn on the power switch Please see our website for more tips innovations industry news and promotional discounts MORE INFORMATION TURNING OFF PRESS 1 Turn the machine off by flipping ON OFF switch when done pressing 2 Unplug and then disconnect the power cord from the press 3 Wait until the press cools down completely to clean and st...

Page 12: ...l RMP2 Press Force 2 Ton Power 300 W Voltage 110 V Frequency 50 60 Hz Dual Heating Plates Yes Platen Size 3 x 3 inch 76 x 76 mm Temperature Range up to 400 F Certifications CE RoHS WARRANTY We provide One Year Warranty Please contact Rositek at support rositek com immediately of any issues with the product We will attempt to troubleshoot the product and solve your issue in a timely manner ...

Reviews: