background image

200Mbps Powerline Pass-Through Fast Ethernet Adapter KIT

          - 

RPLC-201PKIT

-                                            User

’s Manual 

 

-32- 

Appendix D: RPLC-201P QoS Support 

RPLC-201P allows for 4 levels of Channel Access Priority (CAP (0 

– 3)). The 8 levels 

of VLAN Ethernet tags must be mapped to the 4 levels of CAP priority, where CAP 3 

is the highest priority and CAP 0 is the lowest. CAP 3 priority might be used for voice 

and network management frames, and CAP 2 is used for streaming HD video and 

music while CAP 1 and CAP 0 are used for data.   

Default CAP 

The „Default CAP‟ group allows for default priority mapping of packets that do not 

have a VLAN TAG. The settings are available for Unicast (directed to a host). 

 

Unicast  -  (default  CAP  1)  -  sets  the  default  channel  access  priority  for 

unicast frames not matching any other classification or mapping. 

 

IGMP  managed  Multicast  Stream  (Fixed  to  CAP  2)  -  sets  the  default 

channel  access  priority  for  stream  data  belonging  to  a  snooped  IGMP 

multicast group. 

 

IGMP - (default CAP 3) - sets the channel access priority for IGMP frames - 

these are the group management frames, not the stream data. 

 

Multicast/Broadcast  -  sets  the  default  CAP  for  multicast  frames  not  in  a 

snooped group and for broadcast frames. 

The following are the factory fixed settings for QoS Priority: 

 

1st: Network Management Frames and Voice

 

 

2nd: Video and Music Streaming

 

 

3rd: Data Streaming

 

Thank you for purchasing a quality Rosewill Product. 

 
Please register your product at: www.rosewill.com for complete 
warranty information and future support for your product. 
 
Rosewill Customer Service Hotline: 1-800-575-9885 

Rosewill Customer Service Support: 

[email protected]

 

Summary of Contents for RPLC-201P

Page 1: ...200Mbps Powerline Pass through Fast Ethernet Adapter RPLC 201P User Manual...

Page 2: ...Adapter s Button and Connector 7 CHAPTER 2 INTRODUCTION TO UTILITY 9 2 1 UTILITY INSTALLATION 9 2 2 HOW TO USE POWERLINE UTILITY 17 2 2 1 Main Tab 17 2 2 2 Information Tab 22 2 2 3 About Tab 23 2 2 4...

Page 3: ...ill RPLC 201P 200Mbps Powerline Pass Through Fast Ethernet Adapter 2x RJ45 Ethernet Cable 1x Quick Installation Guide 1x Resource CD for RPLC 201P including Rosewill Powerline Utility Quick Installati...

Page 4: ...other via the 128 bit Advanced Encryption Standard AES through RPLC 201P at a high speed transfer rate of 200Mbps and at 10 100mbps LAN support Note Powerline Technology has certain limitations 1 To...

Page 5: ...energy consumption Extra Power Outlet for more Convenience RPLC 201P enables users to access both network connection and power supply to multiple electrical devices with AC pass through design You ca...

Page 6: ...ws 98SE 2000 ME XP 32 64 bit Vista 32 64bit and Win7 32 64 bit otherwise no OS require CPU Intel Pentium III or better clock rate faster than 2 0GHz recommended RAM At least 128MB Screen resolution An...

Page 7: ...Blink Data is being transmitted Off No Ethernet connection Data Green Orange Red On The PLC adapter has connected to the powerline network The Data LED color may vary according to the Data Transmit Q...

Page 8: ...connects to your computer or other Ethernet enabled network device Connecting to the router modem Insert One end of the RJ45 Cable Recommend using Cat 5E cable or above for Gigabit Network environmen...

Page 9: ...stalled please uninstall it and restart your computer 2 1 Utility Installation Please follow the steps below to install the utility 1 Please insert the utility CD into the computer s CD ROM drive Sele...

Page 10: ...t Adapter KIT RPLC 201PKIT User s Manual 10 If your computer has been installed with the latest WinPcap Powerline Utility will be installed directly Proceed to step 11 3 Click Next to continue install...

Page 11: ...11 5 Click I Agree to accept the license agreement of WinPcap 6 Click Install to install WinPcap 4 1 2 Note If WinPcap of an earlier version has been installed in your computer the system notifies you...

Page 12: ...7 If WinPcap of an earlier version has been installed in your computer the system notifies you to uninstall the earlier version when you try installing WinPcap included in the CD Click Yes 8 Click Uni...

Page 13: ...ine Pass Through Fast Ethernet Adapter KIT RPLC 201PKIT User s Manual 13 10 Click Finish to complete installing WinPcap and start to install Powerline Utility 11 Click Next to follow Powerline Utility...

Page 14: ...r KIT RPLC 201PKIT User s Manual 14 12 Select I accept the agreement Click Next to continue installation 13 Click Browse to change the path for installing Powerline Utility The default installation pa...

Page 15: ...RPLC 201PKIT User s Manual 15 14 Create a shortcut in the Start Menu folder Click Browse to select a folder to place the shortcut Click Next to continue the installation 15 Select Create a desktop ic...

Page 16: ...200Mbps Powerline Pass Through Fast Ethernet Adapter KIT RPLC 201PKIT User s Manual 16 16 Click Install to start installing Powerline Utility...

Page 17: ...top or quick launch bar to open Powerline Utility 2 2 1 Main Tab The Main screen provides a list of all powerline devices logically connected to the computer The top panel shows the local HomePlugAV d...

Page 18: ...wever more than one HomePlugAV devices will be detected if your computer has multiple NICs The lower panel displays all the HomePlugAV remote devices discovered in the current logical network The tota...

Page 19: ...get devices password verified by entering correct passwords The steps for entering the password of the device are as follows Step 1 Click the device name to select the device in the lower panel Step...

Page 20: ...ve their password verified can be removed from a network by clicking Change NPW Before changing a device s NPW click Enter Password to enter the device s password to achieve verification If the device...

Page 21: ...ord different from that of the local device s existing network Step 3 Click OK After the network password for the local device is changed successfully this local device is removed from its existing ne...

Page 22: ...Upgrade The Firmware Upgrade button is used to upgrade the device firmware Note Only devices that have their password verified can achieve firmware upgrade by clicking Firmware Upgrade The steps for...

Page 23: ...on the powerline network It includes the following MAC address of all NICs connected to the host MAC address of all devices connected locally to the host network Name NPW of local devices Software ve...

Page 24: ...200Mbps Powerline Pass Through Fast Ethernet Adapter KIT RPLC 201PKIT User s Manual 24 2 2 4 Preferences The lower panel displays options for turning the autoscan function on or off...

Page 25: ...orm a logical network Forming a HomePlug AV logical network Do as follows to form a logical network 1 Press the Security Reset pushbutton on device A or B for 5 8 seconds The device will reset and res...

Page 26: ...he Security Reset button on device C the joiner for less than 3 seconds 3 Within 30 seconds press the Security Reset button on device A or device B for less than 3 seconds 4 Wait for connection to com...

Page 27: ...8 seconds The device will reset and restart with a random NMK 2 Wait for reset to complete The Power indicator on device C momentarily extinguishes during reset blinks during restart and then illumin...

Page 28: ...ix A Improving the Transmission Quality It is important to use the PLC product complying with the following rule of thumb because it can significantly improve the transmission capacity of the network...

Page 29: ...ximum PLC support Capable of extending up to total of 8 Powerline adapters in one environment Connection Type RJ45 Connection Speeds 10 100M Kit Type Double Frequency Band 2 MHz 28 MHz Power Consumpti...

Page 30: ...support Microsoft Windows 2000 XP Vista 7 Dimensions 4 61 x 2 36 x 2 09in 117 x 60 x 53 mm 1 Powerline adapter Weight 0 35 lb 160 g 1 Powerline adapter Temperature 0 C 40 C Operation 20 C 70 C Storage...

Page 31: ...arrier Sense Multiple Access Collision Avoidance DAK Device Access Key DM Device Manager IGMP Internet Group Management Protocol NEK Network Encryption Key NID Network ID Identification NMK Network Me...

Page 32: ...el access priority for unicast frames not matching any other classification or mapping IGMP managed Multicast Stream Fixed to CAP 2 sets the default channel access priority for stream data belonging t...

Page 33: ...he device from the wall outlet before cleaning Use a damp cloth for cleaning Do not use liquid cleaners or aerosol cleaners Do not operate this product near water This product should never be placed n...

Page 34: ...his device does cause harmful interference to radio television reception which can be determined by turning the device off and on the user is encouraged to try to correct the interference by on or mor...