User Manual 

 

7-16 Calibration Kit

  

60CK001-150 and 60CK010-150  

60CK010-150

 

 

 

Rosenberger Hochfrequenztechnik GmbH & Co. KG  
P.O.Box 1260       D-84526 Tittmoning       Germany 
www.rosenberger.com

 

Tel.    : +49 8684 18-0  
 
Email : [email protected]

 

Page 

 

4 / 17

 

 

D

ie

s

e

s

 D

o

k

u

m

e

n

is

u

rh

e

b

e

rr

e

c

h

tl

ic

h

 g

e

s

c

h

ü

tz

 T

h

is

 d

o

c

u

m

e

n

is

 p

ro

te

c

te

d

 b

y

 c

o

p

y

ri

g

h

 R

o

s

e

n

b

e

rg

e

H

o

c

h

fr

e

q

u

e

n

z

te

c

h

n

ik

 G

m

b

H

 &

 C

o

K

G

 

1.3 Kit Contents 

 

Table 1-1   Parts of the 60CK001-150 Calibration Kit 

Device 

Part number 

Remarks 

Quantity 

Open circuit plug 

60S12L-000S3 

 

Open circuit jack 

60K12L-000S3 

 

Short circuit plug 

60S12S-000S3 

 

Short circuit jack 

60K12S-000S3 

 

Calibration load plug 

60S150-C10S3 

 

Calibration load jack 

60K150-C10S3 

 

Calibration adaptor 

plug/plug 

60S121-S20S3 

 

Calibration adaptor 

jack/jack 

60K121-K20S3 

 

Calibration adaptor RPC-N 

plug to 7-16 plug 

05S160-S20S3 

 

Calibration adaptor RPC-N 

jack to 7-16 jack 

05K160-K20S3 

 

Combi wrench 

60W013-000 

16 mm, 20 mm, 25 mm 

Torque wrench 

60W000-003 

32 mm wrench size 

2.26 Nm torque 

Gauge jack 

(including gauge block) 

60W00K-000 

 

Gauge plug 

(including gauge block) 

60W00S-000 

 

 

Table 1-2   Parts of the 60CK010-150 Calibration Kit 

Device 

Part number 

Remarks 

Quantity 

Open circuit plug

 

60S12L-000S3

 

 

1

 

Open circuit jack

 

60K12L-000S3

 

 

1

 

Short circuit plug

 

60S12S-000S3

 

 

1

 

Short circuit jack

 

60K12S-000S3

 

 

1

 

Calibration load plug

 

60S150-C10S3

 

 

1

 

Calibration load jack

 

60K150-C10S3

 

 

1

 

Calibration adaptor 

plug/plug

 

60S121-S20S3

 

 

1

 

Calibration adaptor 

jack/jack

 

60K121-K20S3

 

 

1

 

Combi wrench

 

60W013-000

 

16 mm, 20 mm, 25 mm

 

1

 

Torque wrench

 

60W000-003

 

32 mm wrench size 

2.26 Nm torque

 

1

 

Summary of Contents for 60CK001-150

Page 1: ...nztechnik GmbH Co KG P O Box 1260 D 84526 Tittmoning Germany www rosenberger com Tel 49 8684 18 0 Email info rosenberger com Page 1 17 Dieses Dokument ist urheberrechtlich gesch tzt This document is p...

Page 2: ...it Documentation 1 4 Calibration Certificate 1 5 2 Specifications Environmental Requirements 2 1 Electrical and mechanical Specifications 2 2 3 Standard Definitions Standard Definitions 3 1 Installati...

Page 3: ...t used Contributing factors are noise linearity and temperature stability of the VNA transmission and reflection stability of a test port cable as well as operator experience and care VNAs usually off...

Page 4: ...n adaptor plug plug 60S121 S20S3 1 Calibration adaptor jack jack 60K121 K20S3 1 Calibration adaptor RPC N plug to 7 16 plug 05S160 S20S3 1 Calibration adaptor RPC N jack to 7 16 jack 05K160 K20S3 1 Co...

Page 5: ...for installing Standard Definitions on a Vector Network Analyzer Calibration Certificate See chapter Calibration Certificate User Manual This document 1 5 Calibration Certificate Each calibration kit...

Page 6: ...are defined for all calibration standards gauges and the torque wrench in the specific data sheets 3 Standard Definitions 3 1 Standard Definitions Standard definitions provide the data needed to math...

Page 7: ...more complex process Please consult the VNA operating manual Some network analyzers allow a step by step input of the model based standard definitions during the VNA calibration without previously lo...

Page 8: ...etting parameters Sweep type linear logarithmic Sweep range start frequency stop frequency Number of points frequency step size Source power IF bandwidth small IF bandwidth basically increases the dyn...

Page 9: ...rts and is most effective when data based standards are available In cases when the two VNA test ports have different connector systems installed e g 7 16 and RPC N 50 UOSM can handle this situation A...

Page 10: ...s office Please use the Service Form at the end of this manual if there are any known problems with your calibration kit 5 4 Extent of Rosenberger Re Calibration Services Every calibration kit sent fo...

Page 11: ...d connector repeatability and its effect on the overall uncertainty of a measurement procedure should encourage careful inspection interface gauging and handling of coaxial connectors Prior to use a v...

Page 12: ...ear at least a grounded wrist strap and observe correct procedures 6 2 Interface Dimensions and Gauging It is of the utmost importance that connectors do not damage the test equipment interfaces to wh...

Page 13: ...a gauge jack female all gender are vice versa Checking devices for protrusion or excessive recession only a single measurement is sufficient More precise measurements or checking devices very close t...

Page 14: ...17 Dieses Dokument ist urheberrechtlich gesch tzt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH Co KG 6 2 4 Gauge blocks Every connector gauge requires a gauge block tha...

Page 15: ...r extends beyond the reference length This means a pin depth 1 77 mm on the male connector and a pin depth of 1 77 mm on the female connector Protrusion may result in buckling of the socket contacts o...

Page 16: ...ectors Refer to 6 1 Connector Care 4 Use a connector gauge to verify that all centre conductors do not protrude the pin depth values in Figure 6 2 5 Carefully align the connectors The male connector c...

Page 17: ...disconnecting a sliding load leave the centre conductor pullback handle in the locked position Use the combi wrench to prevent the device body from turning Use torque wrench to loosen the connecting...

Reviews: