User Manual 

 

RPC-2.92 Calibration Kit 

02CK001-150 and 02CK010-150

 

02CK001-150 

 

 

Rosenberger Hochfrequenztechnik GmbH & Co. KG  
P.O.Box 1260       D-84526 Tittmoning       Germany 
www.rosenberger.com

 

Tel.    : +49 8684 18-0  
 
Email : [email protected]

 

Page 

 

2 / 17

 

 

D

ie

s

e

s

 D

o

k

u

m

e

n

is

u

rh

e

b

e

rr

e

c

h

tl

ic

h

 g

e

s

c

h

ü

tz

 T

h

is

 d

o

c

u

m

e

n

is

 p

ro

te

c

te

d

 b

y

 c

o

p

y

ri

g

h

 R

o

s

e

n

b

e

rg

e

H

o

c

h

fr

e

q

u

e

n

z

te

c

h

n

ik

 G

m

b

H

 &

 C

o

K

G

 

Contents 

 
 

1. General Information 

 
Calibration Kit Normal Use 

1.1 

Warnings 

 1.2 

Kit Contents 

1.3 

Kit Documentation 

1.4 

Calibration Certificate 

1.5 

 

2. Specifications 

 
Environmental Requirements 

2.1 

Electrical and mechanical Specifications 

2.2 

 

3. Standard Definitions 

 
Standard Definitions 

3.1 

Installation of Standard Definitions 

3.2 

Standard Definitions file nomenclature 

3.3 

 

4. VNA Calibration 

 
VNA Calibration 

4.1 

Calibration Check 

4.2 

 

5. Calibration Kit Service 

 
Calibration interval 

5.1 

Spare parts 

5.2 

Where to send a Kit for Re-Calibration / Repair 

5.3 

Extent of Rosenberger Re-Calibration Services 

5.4 

 

6. Use, Maintenance and Care 

 
Connector Care 

6.1 

Interface Dimensions and Gauging 

6.2 

Mechanical Specifications 

6.3 

Handling and Storage 

6.4 

 

7. Connections 

 

 

 

Summary of Contents for 02CK001-150

Page 1: ...mbH Co KG P O Box 1260 D 84526 Tittmoning Germany www rosenberger com Tel 49 8684 18 0 Email info rosenberger com Page 1 17 Dieses Dokument ist urheberrechtlich gesch tzt This document is protected by...

Page 2: ...Kit Documentation 1 4 Calibration Certificate 1 5 2 Specifications Environmental Requirements 2 1 Electrical and mechanical Specifications 2 2 3 Standard Definitions Standard Definitions 3 1 Installa...

Page 3: ...ed Contributing factors are noise linearity and temperature stability of the VNA transmission and reflection stability of a test port cable as well as operator experience and care VNAs usually offer s...

Page 4: ...C10S3 1 Calibration load jack 02K150 C10S3 1 Calibration adaptor plug plug 02S121 S20S3 1 Calibration adaptor jack jack 02K121 K20S3 1 Combi wrench 03W008 000 5 mm 6 mm 7 mm 8 mm 9 mm 1 Torque wrench...

Page 5: ...recautions and information for installing Standard Definitions on a Vector Network Analyzer Calibration Certificate See chapter Calibration Certificate User Manual This document 1 5 Calibration Certif...

Page 6: ...ns are defined for all calibration standards gauges and the torque wrench in the specific data sheets 3 Standard Definitions 3 1 Standard Definitions Standard definitions provide the data needed to ma...

Page 7: ...a more complex process Please consult the VNA operating manual Some network analyzers allow a step by step input of the model based standard definitions during the VNA calibration without previously...

Page 8: ...setting parameters Sweep type linear logarithmic Sweep range start frequency stop frequency Number of points frequency step size Source power IF bandwidth small IF bandwidth basically increases the d...

Page 9: ...vailable In cases when the two VNA test ports have different connector systems installed e g RPC 3 50 and RPC 2 40 UOSM can handle this situation A second calibration kit is needed Calibration Procedu...

Page 10: ...calibration or repair contact your local Rosenberger sales office 5 4 Extent of Rosenberger Re Calibration Services Every calibration kit sent for re calibration or repair the following services are...

Page 11: ...ood connector repeatability and its effect on the overall uncertainty of a measurement procedure should encourage careful inspection interface gauging and handling of coaxial connectors Prior to use a...

Page 12: ...wear at least a grounded wrist strap and observe correct procedures 6 2 Interface Dimensions and Gauging It is of the utmost importance that connectors do not damage the test equipment interfaces to...

Page 13: ...or a gauge jack female all gender are vice versa Checking devices for protrusion or excessive recession only a single measurement is sufficient More precise measurements or checking devices very close...

Page 14: ...es Dokument ist urheberrechtlich gesch tzt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH Co KG 6 2 4 Gauge blocks Every connector gauge requires a gauge block that is us...

Page 15: ...in which the centre conductor extends beyond the outer conductor mating plane This may result in buckling of the socket contacts or damage to the internal structure of a device due to the axial force...

Page 16: ...l centre conductors are within the observed pin depth values in Table 2 2 Refer to 4 2 Interface Dimensions and Gaging 5 Carefully align the connectors The male connector centre pin must slip concentr...

Page 17: ...en disconnecting a sliding load leave the centre conductor pullback handle in the locked position Use the combi wrench to prevent the device body from turning Use torque wrench to loosen the connectin...

Reviews: