4-21
Rosemount Tank Radar Rex
Chapter 4 Service
Service Manual
308012En, Ed.2
May 2013
4.1.9
Analog inputs
Rex supports two high precision 4-20 mA analog inputs. Using the
analog inputs requires that the transmitter is equipped with the
Transmitter Interface Card
(TIC).
Analog Input 1 may be used to connect up to 3 HART Slaves (requires
Figure 4-7. Connection of analog input instruments to the Rex Junction
Box.
The Analog Inputs are identified automatically by the software. The TIC
board must be detected before this function is enabled.
Analog inputs are connected to socket X12 for intrinsically safe
connections in the Rex Junction Box. For further information on how to
connect analog inputs see the
TankRadar Rex Installation Manual
.
Note!
Analog inputs can only be enabled at factory.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
X12
Pressure sensor
Water Level sensor
Summary of Contents for TankRadar Rex DAU 2100
Page 2: ......
Page 3: ...www rosemount tg com Service manual Second edition Copyright May 2013 Rosemount Tank Radar AB ...
Page 8: ...Rosemount TankRadar Rex Contents TOC 4 Service Manual 308012En Ed 2 May 2013 ...
Page 116: ...Rosemount Tank Radar Rex Chapter 4 Service 4 72 Service Manual 308012En Ed 2 May 2013 ...
Page 124: ...Rosemount Tank Radar Rex Chapter 5 Calibration 5 8 Service Manual 308012En Ed 2 May 2013 ...
Page 132: ...Rosemount Tank Radar Rex Chapter 6 Troubleshooting 6 8 Service Manual 308012En Ed 2 May 2013 ...
Page 134: ...Rosemount Tank Radar Rex Chapter 7 Spare Parts 7 2 Service Manual 308012En Ed 2 May 2013 ...
Page 146: ...Rosemount Tank Radar Rex Chapter 9 Technical Data 9 10 Service Manual 308012En Ed 2 May 2013 ...
Page 152: ...Rosemount Tank Radar Rex Index 1 6 Service Manual 308012En Ed 2 May 2013 ...
Page 153: ......