KENT SENSORS
Connect coil drive and electrode cables as shown in Figure E-17.
Kent Sensor to
Rosemount 8732
Transmitter
Figure E-17. Generic Wiring
Diagram for Kent Sensors and
Rosemount 8732
Table E-18. Kent Sensor
Wiring Connections
Coils
Electrodes
SCR OUT
ROSEMOUNT 8732
TRANSMITTER
KENT SENSORS
2
1
SIG2
SIG1
SCR OUT
Fuse
Rosemount 8732
Kent Sensors
1
1
2
2
SCR OUT
17
SCR OUT
18
SIG1
19
SIG2
This is a pulsed DC magnetic flowmeter.
Do not connect AC power
to the sensor
or to terminals 1 and 2 of the
transmitter
, or replacement of the
electronics board will be necessary.