![Rosemount 8732 Series Reference Manual Download Page 149](http://html1.mh-extra.com/html/rosemount/8732-series/8732-series_reference-manual_1487411149.webp)
Reference Manual
00809-0100-4663, Rev BA
January 2010
E-9
Rosemount 8732
FISCHER AND PORTER
SENSORS
Connect coil drive and electrode cables as shown in Figure E-6.
Model 10D1418 Sensor
to Rosemount 8732
Transmitter
Figure E-6. Wiring Diagram for
Fischer and Porter Sensor
Model 10D1418 and
Rosemount 8732
Table E-7. Fischer and Porter
Model 10D1418 Sensor Wiring
Connections
ROSEMOUNT 8732 TRANSMITTER
Electrode Connections
U1
U2
G
8
6
7
L1
L2
5
3
2
1
Coil Connections
Rosemount 8732
Fischer and Porter Model 10D1418 Sensors
1
L1
2
L2
Chassis Ground
17
3
18
1
19
2
This is a pulsed DC magnetic flowmeter.
Do not connect AC power
to the sensor
or to terminals 1 and 2 of the
transmitter
, or replacement of the
electronics board will be necessary.
Summary of Contents for 8732 Series
Page 2: ......
Page 4: ......
Page 10: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 TOC 6 ...
Page 26: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 2 14 ...
Page 38: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 3 12 ...
Page 92: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 A 8 ...
Page 186: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 H 8 ...
Page 189: ......