![Rosemount 8712 Reference Manual Download Page 179](http://html1.mh-extra.com/html/rosemount/8712/8712_reference-manual_1487460179.webp)
Reference Manual
00809-0100-4664, Rev BA
January 2010
E-25
Rosemount 8712
Series 8000A/9300A
Sensor to 8712
Transmitter
Connect coil drive and electrode cables as shown in Figure E-23.
Figure E-23. Wiring Diagram for
Foxboro Series 2800 and
Rosemount 8712
Table E-21. Foxboro Series 8000A/9300A Sensor Wiring Connections
Rosemount 8712
Foxboro
Series 8000A/9300A Sensors
1
1
2
2
Chassis Ground
17
Any Shield
18
Black
19
White
INNER/OUTER SHIELD
SH
W*
SH
B*
W
B
2
1
FOXBORO SERIES
8000A/9300A SENSOR
ROSEMOUNT 8712
TRANSMITTER
This is a pulsed DC magnetic flowmeter.
Do not connect AC power
to the sensor
or to terminals 1 and 2 of the
transmitter
, or replacement of the
electronics board will be necessary.