![Rosemount 8712 Reference Manual Download Page 128](http://html1.mh-extra.com/html/rosemount/8712/8712_reference-manual_1487460128.webp)
Reference Manual
00809-0100-4664, Rev BA
January 2010
Rosemount 8712
B-4
SPECIAL CONDITIONS FOR SAFE USE (X):
The relation between ambient temperature, process temperature and temperature class is
to be taken from Table B-3 on page B-5. The electrical data is to be taken from Table B-1 on
page B-4.
Installation Instructions
At ambient temperatures above 50 °C, heat resistant cables with a temperature rating of at
least 90 °C shall be used.
A fuse with a rating of maximum 0,7 A according to IEC 60127-1 shall be included in the
coil excitation circuit if the sensors are used with other flow transmitters.
Table B-1. Electrical Data
Rosemount 8705 and 8711 Sensors
Coil excitation
circuit:
40 V, 0,5 A, 20 W maximum
Electrode circuit:
in type of explosion protection intrinsic safety EEx ia IIC, U
i
= 5 V, l
i
= 0.2 mA, P
i
= 1 mW, U
m
= 250 V
Table B-2. Relation between ambient temperature, process temperature,
and temperature class
(1)
(1) This table is applicable for KD approval codes only.
Meter Size (Inches)
Maximum Ambient
Temperature
Maximum Process
Temperature
Temperature
Class
1
/
2
115°F (65°C)
239°F (115°C)
T3
1
149°F (65°C)
248°F (120°C)
T3
1
95°F (35°C)
95°F (35°C)
T4
1
1
/
2
149°F (65°C)
257°F (125°C)
T3
1
1
/
2
122°F (50°C)
148°F (60°C)
T4
2
149°F (65°C)
257°F (125°C)
T3
2
149°F (65°C)
167°F (75°C)
T4
2
104°F (40°C)
104°F (40°C)
T5
3 - 36
149°F (65°C)
266°F (130°C)
T3
3 - 36
149°F (65°C)
194°F (90°C)
T4
3 - 36
131°F (55°C)
131°F (55°C)
T5
3 - 36
104°F (40°C)
104°F (40°C)
T6
6
115°F (65°C)
275°F(135°C)
T3
6
115°F (65°C)
230°F (110°C)
T4
6
115°F (65°C)
167°F (75°C)
T5
6
140°F (60°C)
140°F (60°C)
T6
8-60
115°F (65°C)
284°F (140°C)
T3
8-60
115°F (65°C)
239°F (115°C)
T4
8-60
115°F (65°C)
176°F (80°C)
T5
8-60
115°F (65°C)
156°F (69°C)
T6
Summary of Contents for 8712
Page 2: ......
Page 4: ......
Page 26: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 2 16 ...
Page 84: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 4 46 ...
Page 102: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 5 18 ...
Page 114: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 6 12 ...
Page 154: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 D 6 ...
Page 194: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 E 40 ...
Page 208: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 F 14 ...
Page 211: ......