SECURITY_IO
65
0:
Uninitialized
1: Off
2: On
0
E
Read
Only
Status of Security jumper/switch
SIMULATE_
STATE
66
0 - 3
1
E
Read
Only
The state of the simulate jumper
0 = Uninitialized
1 = Jumper/switch off, simulation not allowed
2 = Jumper/switch on, simulation not allowed (need to cycle
jumper/switch)
3 = Jumper/switch on, simulation allowed
DOWNLOAD_
MODE
67
0 - 2
1
E
Gives access to the boot block code for over the wire
downloads
0 = Uninitialized
1 = Run Mode
2 = Download Mode
RECOMMENDED
_ACTION
68
0
E
Read
Only
Enumerated list of recommended actions displayed with a
device alert.
FAILED_PRI
69
0 - 15
0
N/A
Designates the alarming priority of the FAILED_ALM.
FAILED_ENABLE
70
0
E
Read
Only
Enabled FAILED_ALM alarm conditions. Corresponds bit for
bit to the FAILED_ACTIVE. A bit on means that the
corresponding alarm condition is enabled and will be
detected. A bit off means the corresponding alarm condition is
disabled and will not be detected.
FAILED_MASK
71
See Table 25
0
E
Mask of FAILED_ALM. Corresponds bit of bit to
FAILED_ACTIVE. A bit on means that the condition is
masked out from alarming.
FAILED_ACTIVE
72
0
E
Read
Only
Enumerated list of failure conditions within a device.
FAILED_ALM
. Unacknowledged
. Alarm State
. Time Stamp
. Subcode
. Value
73
N/A
R/W
RO
RO
RO
RO
Alarm indicating a failure within a device which makes the
device non-operational.
Only “Unacknowledged” subindex is writeable (R/W). The rest
are Read Only (RO)
MAINT_PRI
74
0 - 15
0
N/A
Designates the alarming priority of the MAINT_ALM
MAINT_ENABLE
75
0
E
Read
Only
Enabled MAINT_ALM alarm conditions. Corresponds bit for
bit to the MAINT_ACTIVE. A bit on means that the
corresponding alarm condition is enabled and will be
detected. A bit off means the corresponding alarm condition is
disabled and will not be detected.
MAINT_MASK
76
See Table 26
0
E
Mask of MAINT_ALM. Corresponds bit of bit to
MAINT_ACTIVE. A bit on means that the condition is masked
out from alarming.
MAINT_ACTIVE
77
0
E
Read
Only
Enumerated list of maintenance conditions within a device.
MAINT_ALM
. Unacknowledged
. Alarm State
. Time Stamp
. Subcode
. Value
78
N/A
R/W
RO
RO
RO
RO
Alarm indicating the device needs maintenance soon. If the
condition is ignored, the device will eventually fail.
ADVISE_PRI
79
0 - 15
0
N/A
Designates the alarming priority of the ADVISE_ALM
ADVISE_
ENABLE
80
0
Read
Only
Enabled ADVISE_ALM alarm conditions. Corresponds bit for
bit to the ADVISE_ACTIVE. A bit on means that the
corresponding alarm condition is enabled and will be
detected. A bit off means the corresponding alarm condition is
disabled and will not be detected.
Parameter
Index
Valid Range
Initial Value
Units
Other
Description
Summary of Contents for 752
Page 2: ......
Page 4: ......
Page 10: ...Reference Manual 00809 0100 4377 Rev BA September 2010 Rosemount 752 1 4 ...
Page 26: ...Reference Manual 00809 0100 4377 Rev BA September 2010 Rosemount 752 2 16 ...
Page 38: ...Reference Manual 00809 0100 4377 Rev BA September 2010 Rosemount 752 A 4 ...
Page 43: ...Reference Manual 00809 0100 4377 Rev BA September 2010 B 5 Rosemount 752 APPROVAL DRAWINGS ...
Page 44: ...Reference Manual 00809 0100 4377 Rev BA September 2010 Rosemount 752 B 6 ...
Page 45: ...Reference Manual 00809 0100 4377 Rev BA September 2010 B 7 Rosemount 752 ...
Page 46: ...Reference Manual 00809 0100 4377 Rev BA September 2010 Rosemount 752 B 8 ...
Page 47: ...Reference Manual 00809 0100 4377 Rev BA September 2010 B 9 Rosemount 752 ...
Page 48: ...Reference Manual 00809 0100 4377 Rev BA September 2010 Rosemount 752 B 10 ...
Page 59: ......