Reference Manual
00809-0100-4708, Rev AA
June 2010
2-1
Rosemount 708
Section 2
Configuration
Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1
Device Sensor Configuration . . . . . . . . . . . . . . . . . . . . . . page 2-1
Device Network Configuration . . . . . . . . . . . . . . . . . . . . . page 2-2
Remove Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-5
SAFETY MESSAGES
Instructions and procedures in this section may require special precautions to
ensure the safety of the personnel performing the operations. Information that
potentially raises safety issues is indicated by a warning symbol ( ). Please
refer to the following safety messages before performing an operation
preceded by this symbol.
Warnings
DEVICE SENSOR
CONFIGURATION
Remove the power module housing then connect to the HART
communication terminals for configuration.
The Rosemount 708 will receive any HART communication from a handheld
Field Communicator, or AMS
®
. When using a Field Communicator, any
configuration changes must be sent to the transmitter using the
Send
key
(F2). AMS configuration changes are implemented when the
Apply
button is
clicked.
AMS
®
Wireless Configurator
AMS is capable of connecting to devices directly, using a HART modem, or
with the Gateway. When configuring on the bench with a HART modem,
double click the device icon, then choose the Configure/Setup tab (or right
click and select Configure/Setup). Configure the device settings using the
Direct Connection menu. When configuring with the Gateway, double click the
device icon then choose the Configure/Setup tab (or right click and select
Configure/Setup). Configure the device settings using the Wireless
Connection menu.
To check or change sensor configuration using a 475 Field Communicator,
enter the following Fast Key Sequence:
X, X, X
.
Failure to follow these installation guidelines could result in death or serious injury
:
•
Only qualified personnel should perform the installation
Explosions could result in death or serious injury.
•
Before connecting a Field Communicator in an explosive atmosphere, make
sure that the instruments are installed in accordance with intrinsically safe or
non-incendive field wiring practices
•
Verify that the operating atmosphere of the transmitter is consistent with the
appropriate hazardous locations certifications
Electrical shock could cause death or serious injury.
•
Use extreme caution when making contact with the leads and terminals
Summary of Contents for 708
Page 2: ......
Page 6: ...Reference Manual 00809 0100 4708 Rev AA June 2010 Rosemount 708 TOC 2 ...
Page 12: ...Reference Manual 00809 0100 4708 Rev AA June 2010 Rosemount 708 1 6 ...
Page 13: ...Reference Manual 00809 0100 4708 Rev AA June 2010 Rosemount 708 1 7 ...
Page 14: ...Reference Manual 00809 0100 4708 Rev AA June 2010 Rosemount 708 1 8 ...
Page 20: ...Reference Manual 00809 0100 4708 Rev AA June 2010 Rosemount 708 2 6 ...
Page 23: ...Reference Manual 00809 0100 4708 Rev AA June 2010 3 3 Rosemount 708 ...
Page 24: ...Reference Manual 00809 0100 4708 Rev AA June 2010 Rosemount 708 3 4 ...
Page 25: ...Reference Manual 00809 0100 4708 Rev AA June 2010 3 5 Rosemount 708 ...
Page 26: ...Reference Manual 00809 0100 4708 Rev AA June 2010 Rosemount 708 3 6 ...
Page 30: ...Reference Manual 00809 0100 4708 Rev AA June 2010 Rosemount 708 4 4 ...
Page 42: ...Reference Manual 00809 0100 4708 Rev AA June 2010 Rosemount 708 B 6 ...
Page 43: ......