![Rosemount 5300 Series Reference Manual Download Page 341](http://html1.mh-extra.com/html/rosemount/5300-series/5300-series_reference-manual_1487396341.webp)
May 2016
Reference Manual
00809-0100-4530, Rev DD
327
Appendix D
Remote Mounting
Remote housing, new units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 327
Remote connection, field retrofit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 327
Installing remote housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 328
Remote housing configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 330
D.1
Remote housing, new units
Remote Housing can be used to place the head apart from the probe if it is in a hot or
vibrating place. With Remote Housing, you can place the transmitter head in a better
position to be able to read the display, for example.
The remote housing assembly is shipped with the transmitter head mounted on the probe
and the remote connection in a separate box.
The transmitter head must have the remote connection installed before functioning.
The parts in the shipping unit consist of:
Transmitter head mounted on probe
Remote connection
Bracket kit
- Bracket (1 pcs)
- Clamping bracket (4 pcs)
- U-bolt (2 pcs)
- M6 screw (3 pcs)
- M6 nut (4 pcs)
D.2
Remote connection, field retrofit
To upgrade a currently installed Rosemount
™
5300 Transmitter with a remote housing, the
embedded software needs revision 2.A2 or later, and the Spare Part Kit (03300-7006-000X)
must be ordered. The position X corresponds to the remote housing cable length in meters.
The Rosemount 5300 Transmitter head must be configured for remote housing to work.
The Spare Part Kit consists of:
Remote connection
Bracket kit
- Bracket (1 pcs)
- Clamping bracket (4 pcs)
- U-bolt (2 pcs)
- M6 screw (3 pcs)
- M6 nut (4 pcs)