INSTALLATION, OPERATION, & MAINTENANCE MANUAL
Rosedale Engineering Standards are the property of Rosedale Products, Inc. A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale
Products, Inc.) to any individual or firm beyond the intended recipient firm or individual. Firms of individuals acting contrary to the above may be subject to suit, ineligibility for continued or
future employment, or removal from Rosedale’s "Approved Manufacturers and Specialty Contractors List".
Rosedale Products, Inc. Model 8 & Multi Bag, Single Pass (
SP
) and Recirculating System
(
RS
) basket assembly has been designed to allow for easy installation and replacement of various
filter media’s.
Rosedale Products, Inc. recommends using a bag filter down stream from the
SP
or
RS
basket assembly to filter out any contaminations the Filter Media may introduce into the system.
Type of filter media is dependent on your particular filtering requirements. If Carbon Filter
Media is used it is recommended to rinse the Carbon to remove unwanted dust & to prevent
contamination of down stream fluids.
Rosedale Products Model 8 & Multi Bag, SP and RS basket assembly consist of the
following parts (See diagram on page 4).
1.
Basket
2.
O-ring seal
3.
Screw on cover
4.
Filter media (customer to order separately)
5.
Basket seal (supplied with housing)
Filter Media Installation
1.
Remove (unscrew) cover from basket assembly.
2.
Remove O-ring seal from groove in basket support web. Inspect O-ring for cracks
and/or splitting. Replace if damaged.
3.
Add filter media in media fill area (3 slots in top of basket support ring).
4.
Clean excess media from O-ring groove and off top of basket support ring.
5.
Place O-ring seal in clean O-ring groove.
6.
Replace basket cover and tighten down to seal.
7.
Inspect basket seal for cracks and/or splitting. Replace if damaged.
8.
Install basket seal.
8.1 In housing (M-8)
8.2 In basket flange (MB)
9.
Install basket in filter housing and secure cover.
10.
Follow standard Filter System Start-Up Procedure found in the filter
INSTALLATION, OPERATION AND MAINTENANCE MANUAL.