Rose electronics UltraMatrix AV Quick Start Manual Download Page 2

Unit Installation 

   

 

Getting Started 

 (IT IS RECOMMENDED THAT ALL EQUIPMENT BE POWERED OFF UNTIL ALL 
CONNECTIONS HAVE BEEN MADE) 
 
Hardware Installation       (System must include one master and one secondary unit) 
 

 

 
                 (Installation is performed for each computer (1-16) that is connected to the unit) 
  

1. 

Connect a serial ”Y” cable (DB9MF) from both UltraMatrix A/V RS232 ports (DB9F) to 
the serial port on the controlling computer.   

2. 

Connect up to 16 computers that have your video content to the HD15F video input 
connectors labeled In 1-16 on both units using a HD15 MM “Y” cable. 
Keep video synchronized; connect to port #1 on the master and port #1 on the 
secondary, port #2 on the master and port #2 on the secondary, etc. 

3. 

Connect up to 16 optional audio inputs (Usually from the 16 corresponding computers) 
to the 3.5mm audio inputs labeled In1-16) using an audio “Y” cable. 

4. 

Connect up to 32 display monitors to the HD15F video output connectors labeled 
OUT1-16 on unit #1 and OUT1-16 on unit #2 using the existing monitor cable or an 
extension cable for greater distances. 

5. 

Connect up to 32 optional stereo audio speakers to the 3.5mm audio inputs labeled 
Out1-16) on unit #1 and Out1-16 on unit #2. 

6. 

Connect a power cord to the power port on each unit and to a 100/240 VAC power 
source  

7. 

Apply power to all connected computers and remote monitors. 

 

   

   

Serial Y cable 

Video Y cable 

Controlling computer 
running RoseControl 

Secondary Unit 
Identified by /NR 
suffix on part number 
 
 
 
 
Master Unit  
Identified by NO /NR 
suffix on part number 