ULTRAMATRIX AV DVI INSTALLATION AND OPERATIONS MANUAL

 

 

Router Type: 

Select “Matrix DVI 16x16”  

 
Inputs/Outputs: 

Enter the number of Inputs/Outputs for your UMAV DVI 16x16.  

 

Com Port: 

Select the appropriate com port that your computer is using to access the router. 

 

Router Time out: 

By default this is 0.2, meaning the computer acknowledges commands almost instantly.  

 
After you have entered the necessary information, click OK. This will now take you to the Main Routing 
Window where you can route the different video/ audio connections. 
 

 

Figure 8. Main Routing Window

 

 
 

On this screen you will notice the input buttons running down the left side while the output buttons run across 
the top. They are labeled 1 through 16.  
 
The Main Routing Window enables you to control the router’s connections by means of the crosspoint panel, 
the buttons, or with pre-recorded routes called macros.  
 

Summary of Contents for UltraMatix AV DVI

Page 1: ...UltraMatrix AV DVI 16x16 DVI VIDEO MATRIX SWITCH 10707 Stancliff Road Phone 281 933 7673 Houston Texas 77099 www rose com INSTALLATION AND OPERATIONS MANUAL...

Page 2: ......

Page 3: ...ERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO A PERIOD OF ONE YEAR FROM THE DATE OF PURCHASE AND NO WARRANTIES WHETHER EXPRESS OR IMPLIED WILL APPLY AFTER THIS PERIOD...

Page 4: ...be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital...

Page 5: ...the IP address on the UMA 16Dx16D RCI 14 Figures Page Figure 1 System Application Overview 4 Figure 2 Connection Diagram 5 Figure 3 Front Panel Buttons 6 Figure 4 UltraMatrix AV DVI Default Display 6...

Page 6: ...two procedures 1 Connecting the video sources and destination monitors to the unit 2 Installing the access software for controlling the UltraMatrix AV DVI Each video source is connected to one of the...

Page 7: ...nel RS 232 IR and TCP IP optional Power Internal 100 240 VAC Dimensions 19 W x 5 25 H 2U x 7 D Weight 10 lbs DVR 16X16 Approvals FCC CE RoHS Compliant Power Supply Approvals UL CE CSA CEC RoHS Environ...

Page 8: ...Application Overview Corporate or Educational Presentations Financial Remote servers Call Centers for Technical Support Industrial Long Range Workstation Isolation Airport Installations Air Traffic C...

Page 9: ...splays Connect the male to male DVI extension cables to the input devices and to the IN ports on the UltraMatrix AV DVI Connect the displays to the OUT ports on the UltraMatrix AV DVI Connect the powe...

Page 10: ...t it is locked Repeat the procedure to unlock the front panel During normal operation you will see a list of ports on the front panel display Figure 4 UltraMatrix AV DVI Default Display To assign an o...

Page 11: ...send a confirmation that an RS 232 command has been received Send Update Sets the UltraMatrix AV DVI to send an RS 232 command back to the controller when the configuration is changed via the front pa...

Page 12: ...elp File UltraMatrix AV DVI Manual in PDF format Double click RoseControl_Installer exe in order to initiate software installation Click Install After installation has completed click CLOSE In order t...

Page 13: ...commands almost instantly After you have entered the necessary information click OK This will now take you to the Main Routing Window where you can route the different video audio connections Figure 8...

Page 14: ...s Simply click on the cross point itself The input on the left will then be routed to the output above Note Inputs can be routed to several different outputs but each output can only have a single inp...

Page 15: ...cros store a set sequence of routes To record a macro 1 Click on the Record button last button shown A blinking recording message below this button will be displayed to indicate that all routes are be...

Page 16: ...ginal container or equivalent insured and shipped to Rose Electronics Attn RA__________ 10707 Stancliff Road Houston Texas 77099 USA Technical Support If you are experiencing problems or need assistan...

Page 17: ...t might cause damage to them Use only power cords and connection cables designed for this Unit Use only a grounded three wire electrical outlet Keep objects that might damage this Unit and liquids tha...

Page 18: ...t s RJ45 port to a computer configured with an Ethernet card and Window s operating system XP or Vista Use a network cable to connect the computer to unit Figure 10 Connecting the Network Cable 2 Acce...

Page 19: ...network settings for the unit in the Network Setting page Figure 13 RoseControlIP Network Setting page 7 Enter the desired IP address and network mask for the unit and click the Activate button to app...