5.  Disconnect the unit from the electrical outlet before cleaning, filling and after 

each use. 

6.  Do not use other attachments unless recommended by manufacturer. 

 
OPERATING CAUTIONS: 

1.  Connect this product to an appropriate voltage outlet for your model. Do not 

use with power strips or extension cords.   

2.  Do not run this product unattended. 
3.  Never operate if this unit has a damaged cord or plug, if it has been dropped, 

or in any way, into water, if it does not work properly. Return it to a service 
center for repair. 

4.  If any abnormality occurs, discontinue use immediately until the unit has 

been examined and repaired. 

5.  Always unplug the product immediately after use. 
6.  Never allow the power supply cord to be pulled, jerked, strained, twisted or 

severely bent, especially at the plug connections. Damage will occur at the 
high flex point of entry into the appliance, causing it to rupture and short. 
Handle the cord carefully for longer life. 

7.  Never block the air openings of the main unit or place it where the air 

openings may be obstructed. 

 

STORAGE CAUTIONS: 

1.  Do not store the unit under direct sunlight, high temperature or humidity. 
2.  Keep the unit out of reach of small children. 
3.  Keep the cord away from heated surfaces. Do not wrap the cord around   

the appliance. 

4.  Always keep the unit unplugged while not in use. 
 

CLEANING CAUTIONS: 

1.  Do not immerse the unit in water. It may damage the unit. 
2.  Disconnect the unit from the electrical outlet before cleaning. 
3.  Clean all necessary parts after each use as instructed in this guidebook. 
 
 

4.    OPERATING YOUR COMPRESSOR NEBULIZER 
 
Note

: Prior to initial operation, the nebulizer should be thoroughly cleaned. 

 
1.  Place your Compressor Nebulizer on a flat and stable surface. Be sure that 

you can easily reach the controls when you are seated. 

2.  Get accessories ready. 

Important

: Prior to initial operation, the nebulizer should be thoroughly 

cleaned referring to the “Cleaning Procedures” in the manual. 

3.  Gently twist the top part of the nebulizer counter-clockwise to disassemble 

the nebulizer.   

 

Summary of Contents for NEB-ROS

Page 1: ...1 ROSCOE MEDICAL MINI COMPRESSOR NEBULIZER Guidebook MODEL NEB ROS READ THIS INSTRUCTION...

Page 2: ...deliver physician prescribed medication to the bronchial lung passages and is intended for home health care use With proper care and use it will provide you with many years of reliable treatment This...

Page 3: ...HOULD BECOME DETACHED OR BROKEN EXPOSING THE MOTOR OR ANY OTHER ELECTRICAL COMPONENTS OPERATION SHOULD BE DISCONTINUED IMMEDIATELY TO AVOID PERSONAL INJURY OR FURTHER PRODUCT DAMAGE 2 To avoid electri...

Page 4: ...arefully for longer life 7 Never block the air openings of the main unit or place it where the air openings may be obstructed STORAGE CAUTIONS 1 Do not store the unit under direct sunlight high temper...

Page 5: ...cool down before another treatment Make sure the air openings are not obstructed 11 When treatment is finished shut off the unit and unplug it from the electrical outlet 5 CLEANING It is recommended t...

Page 6: ...Replace the filter cover 6 REPLACEMENT PARTS OPTIONAL ACCESSORIES Replacement parts are available through your local retailer Optional accessories include adult child masks and baby pacifier inhalers...

Page 7: ...defects in materials and workmanship If within such warranty period the product proves defective the product will be repaired or replaced at the option of Roscoe Medical This warranty does not cover d...

Page 8: ...8 ROSCOE MEDICAL MINICOMPRESOR NEBULIZADOR Gu a MODELO NEB ROS LEA DETENIDAMENTE ESTE MANUAL DE INSTRUCCIONES ANTES DE USAR EL PRODUCTO...

Page 9: ...res y su uso es para cuidado en casa Con el cuidado y uso adecuados le proporcionar muchos a os de tratamiento confiable Este producto se desarroll para el tratamiento exitoso del asma alergias y otro...

Page 10: ...E SEPARARSE O DESCONTINUARSE O EL MOTOR U OTROS COMPONENTES EL CTRICOS QUEDAN EXPUESTOS DEBE SUSPENDER EL FUNCIONAMIENTO DE INMEDIATO PARA EVITAR LESIONES PERSONALES U OTROS DA OS EN EL PRODUCTO 2 Nun...

Page 11: ...para mantener su vida til 7 Nunca bloquee los respiraderos de la unidad principal tampoco debe colocarla en un lugar donde los respiraderos queden obstruidos MEDIDAS DE PRECAUCI N PARA EL ALMACENAMIEN...

Page 12: ...e sobrecaliente Cuando el protector t rmino apague la unidad por favor a Apague la unidad con el interruptor b Desenchufe la unidad del tomacorriente c Espere 40 minutos a que el motor se enfr e antes...

Page 13: ...por su distribuidor No ponga a funcionar el aparato sin filtro 2 Cambie el filtro cada 30 d as o cuando el filtro se vuelva gris 3 Procedimiento para cambiar el filtro a Quite la tapa del filtro b Cam...

Page 14: ...iezas Accesorios opcionales Mascarilla para adulto mascarilla infantil tubo de extensi n adaptador en T Garant a 5 a os de garant a limitada Protecci n contra descargas el ctricas Equipo Clase II Part...

Page 15: ...s del aparato causadas por negligencia o mal uso por parte del propietario o por desgaste normal Esta garant a no se extiende a los componentes no duraderos que est n sujetos al desgaste normal y nece...

Page 16: ...16 Fabricado para Roscoe Medical 21973 Commerce Parkway Strongsville Ohio 44149 Impreso en China...

Reviews: