14
3.) Wiring Instructions
Your Rosco X-Effects LED Projector will include a detached power+data cable with female UTL connector
that mates with the connector on the back of the luminaire. Units sold in North America will utilize a cable
harness assembly. Units sold outside of North America will utilize a hybrid power+ data cable. The user end
of the cables are unterminated and should be connected to appropriate power and data supplies.
Note: Power and data connections should be performed by a qualified electrician and are the responsibility
of the installer or end user.
The power wiring color-code for all product sold in North America is as follows:
Black – Live/Hot lead
White – Neutral lead
Green – Ground
The data wiring color-code is as follows:
DMX IN
Red:
Data+
Black: Data –
Shield: Ground
DMX OUT
Green: Data+
White:
Data-
Shield: Ground