DMX oPeRaTIon

A single channel is required for output intensity control via DMX. In order to set the DMX address, an optional 
DMX Programming Cable (sold separately) is needed, as well as the free Image Spot Addressing Software that 
can be downloaded at www.rosco.com/ImageSpot.  

To set the DMX address on the Image Spot IP40 unit, you will need the USB to RJ45 Cable accessory, sold 
separately. Plug the USB connector into the computer running the Image Spot Addressing Software, and the 
RJ45 connector into the receiver on the rear panel of the fixture. Follow the prompts from the software to set 
address (set value).  The output of the unit can also be tested by entering a value between 255 (100%) and 1 (0%).

Summary of Contents for 296000040401

Page 1: ...plies to the following Rosco Image Spot models Image Spot IP40 Black 296000040401 White 296000040402 Silver 296000040403 Image Spot IP65 Black 296000040651 White 296000040652 Silver 296000040653 Image...

Page 2: ...2...

Page 3: ...fusion Filters 15 Dichroic Color Filters 16 Accessories 17 Ordering Gobos Permacolor Filters 18 Technical Specifications 19 Warranty 20 Information and specifications in this document are subject to c...

Page 4: ...controls Image Spot is available in durable indoor IP40 and outdoor IP65 versions To ensure efficient and safe operation please take a few moments to read this manual completely IMPORTANT SAFEGUARDS T...

Page 5: ...use extension cords or adapter plugs to connect this machine to a two wire system Operation without a safety ground may result in hazardous electrical shock Use only extension cords that are of appro...

Page 6: ...Keep minimum 4 inches 10cm distance away from flammable materials objects Contact with the fixture during or immediately following operation may result in burns Allow the unit to cool before attempti...

Page 7: ...equires that an Image Spot focusing lens tube purchased separately be inserted into the opening on the front of the unit prior to operation Three lens options are available providing Narrow Medium and...

Page 8: ...r end of the lens tube into the opening on the front of the projector IP65 Units Slip the 2 provided O rings onto the grooves on the back end of the lens tube Gently insert the end of the lens tube wi...

Page 9: ...chase or to line voltage should be performed by a qualified electrician and is the responsibility of the installer or end user The power cord wiring code is as follows Core No1 Live Hot Lead Core No2...

Page 10: ...be installed in the desired location via the center hole in the yoke Adjust pan as required Adjust and fix the tilt of the projector via 1 the knurled thumb knob or 2 optional hex screw supplied with...

Page 11: ...e prior to inserting the cassette into the accessory slot Be sure to tighten the thumb screws on the gobo cassette after re inserting to maintain protection from dust and moisture A flat tipped screw...

Page 12: ...to clean the Image Spot lenses and any glass gobos or Permacolor dichroic glass filters you may have installed DIMMING CONTROL The Rosco Image Spot projector offers two modes of control Manual dimming...

Page 13: ...d at www rosco com ImageSpot To set the DMX address on the Image Spot IP40 unit you will need the USB to RJ45 Cable accessory sold separately Plug the USB connector into the computer running the Image...

Page 14: ...nning the Image Spot Addressing Software and wire the cable s multi pin terminal block to the bare ends of the fixture s DMX cable using the following terminal assignment o Terminal 1 Data Blue o Term...

Page 15: ...n Image Spot s beam for spot lighting purposes The OPTI FLECS Filter Pack includes Retaining Ring Soft Diffusion 43mm dia Smoothing Frost 43mm dia Double Powder Frost 43mm dia To install OPTI FLECS fi...

Page 16: ...feature custom bezels to fit securely inside the Image Spot gobo cassette Install the Image Spot Permacolor Filter into the gobo cassette The gobo cassette is deep enough to accept both an Image Spot...

Page 17: ...pot Medium Angle Lens Optic 25 296000010030 Image Spot Wide Angle Lens Optic 30 296000010013 Image Spot OPTI FLECS Filter Pack with Retaining Ring 296000010012 Image Spot Safety Cable 3 ft 1m 29600001...

Page 18: ...260CUSBWOSPO Image Spot Custom B W Glass Gobo 260CUS1COSPO Image Spot Custom One Color Glass Gobo 260CUS2COSPO Image Spot Custom Two Color Glass Gobo 260CUSMCOSPO Image Spot Custom Multi Color Glass G...

Page 19: ...Gobo with custom carrier Working Environment Ambient Temp Working temperature 10 C 40 C 14 F 104 F Humidity 20 90 RH non condensing Data DMX 512 RJ45 Connector IP40 Optional Cat5e Cable IP65 Approval...

Page 20: ...sco as per the instructions of the Return Authorization Within North America Rosco will ship the repaired or replaced Product to you freight prepaid Shipments to other locations will be made freight c...

Page 21: ...PURPOSE EXCEPT AS PROVIDED IN THIS WRITTEN WARRANTY AND UNLESS EXCLUSIONS ARE SPECIFICALLY FORBIDDEN BY STATE LAW NEITHER ROSCO NOR ITS AFFILIATES WILL BE LIABLE FOR ANY LOSS INCONVENIENCE OR DAMAGE I...

Page 22: ...www rosco com imagespot 5007481...

Reviews: