background image

52-51413   REV B 

 

 
The  pins  on  the  camera  connector  should  be  cleaned  and  dried  then  sprayed  with  a 
silicone-based lubricant.  Grease should not be used on enclosed connectors such as the 
standard LPMBH series.  Grease will eventually become impacted in the mating connector, 
forcing the contacts apart and causing intermittent operation. 
 

3.3  CAMERA BOOT-UP SEQUENCE 

 
When  the  camera  is  energized,  the  video  signal  consists  of  a  blue  screen  for  5  to  7 
seconds. Then the video as seen by the camera is displayed. 

 

 

NOTE:

  

While the camera is booting up, all RS-485 commands will be ignored. Only 
after video is displayed on the screen will RS-485 commands be accepted. 

 

3.4  EXPOSURE CONTROL 

 
The RS-485 CEX-HD Camera provides operation over a wide range of scene illuminations. 
 For most operations, it is recommended to simply leave the camera in automatic exposure 
mode,  as  it  generally  does  very  well  at  optimizing  itself  for  the  ambient  illumination 
conditions. 
 
 
In the event that manual Exposure Control is desired due to unusual viewing conditions 
such as severe reflections or flashing lights, the IC-LINK must send a manual Exposure 
command followed by direct Iris position commands.  The operator normally adjusts the 
joystick slider to send a direct Iris position command until an optimum display is seen on 
the television monitor. 
 
To restore automatic Exposure Control: the IC-LINK must send EXP AUTO command. 

3.5  ZOOM CONTROL 

 
The zoom lens operates whenever the IC-LINK sends direct Zoom position commands.  
The zoom function continues until the Zoom position reaches its commanded position or 
the lens zoom limit is reached.  The zoom position is relative to the position of the joystick 
slider, moving the slider forward corresponds to Tele and moving the slider backwards 
corresponds to Wide.  Tele operates towards increasing focal length settings  providing 
reduced  viewing  angles  with  increased  magnification  of  objects  in  the  scene.    Wide 
operation reduces focal length settings increasing viewing angles and allows viewing of 
greater areas of a scene.  
 
When zooming towards the tele end from the full wide end, the optical zoom is activated 
until the optical zoom limit is reached.  

Summary of Contents for RS-485 CEX-HD

Page 1: ...B ROS RS 485 CEX HD 30 1 COLOR ZOOM CAMERA OPERATION AND MAINTENANCE MANUAL SERIAL NUMBER __________ SALES ORDER __________ 5618 Copley Drive San Diego CA 92111 7902 TEL 858 565 8500 FAX 858 565 8808...

Page 2: ...52 51413 REV B II STANDARD ORDERING FORMAT FOR THE RS 485 CEX HD CAMERAS...

Page 3: ...4 2 8 ENVIRONMENTAL 4 2 9 RS 485 CEX HD CONNECTORS 4 2 10 CAMERA INTERCONNECTIONS 5 3 CAMERA OPERATION 6 3 1 GENERAL 6 3 2 INSTALLATION 6 3 3 CAMERA BOOT UP SEQUENCE 7 3 4 EXPOSURE CONTROL 7 3 5 ZOOM...

Page 4: ...his warranty shall be governed by the laws of the State of California In the event the defect is determined to be within the terms of this warranty then ROS agrees to repair and or replace at ROS disc...

Page 5: ...sistance during installation and or operation of these products If you have any questions or problems with this product that are not covered by this manual or instruction please contact our agent in y...

Page 6: ...52 51413 REV B VI CHANGE RECORD REV DESCRIPTION DATE A PRODUCTION RELEASE EC 03235 24AUG20 B SEE EC 03310 19JAN21...

Page 7: ...ural but hostile environments The front window is made of impact resistant optical grade acrylic and utilizes a single O ring seal The RS 485 CEX HD camera utilizes a high resolution Exmor R CMOS imag...

Page 8: ...Ratio 52 Db Video Output HD TVI Zoom Range 30 1 optical 4 3 to 129 0 mm focal length OR Digital Zoom 12x 360x with optical zoom combined Field of View In Air 71 3o Diagonal full wide angle 58 9oH x 45...

Page 9: ...ual Manual uses direct iris position Video Negative Art Negates the video signal can help with contrast in some applications Video B W Transform the color video into black white video Image Flip Puts...

Page 10: ...c 2 8 ENVIRONMENTAL Operating Temperature 0 C to 50o C 32 F to 122 F Storage Temperature 20oC to 60oC Depth Rating 70 m 230 ft 2 9 RS 485 CEX HD CONNECTORS Hydrogroup LPMBH 6 MP 01 configuration Endbe...

Page 11: ...conn MCBHRA 8 MP Inline Mating Connector Subconn MCIL 8 F Figure 2 MCBHRA 8 MP Face View 2 10 CAMERA INTERCONNECTIONS CONNECTOR PIN FUNCTION 1 Camera Power Input 11 to 26 VDC 2 VDC Return 3 RS 485 A 4...

Page 12: ...amage not covered under warranty For LPMBH 6 MP configuration 01 the logos will be aligned as shown in Figure 3 when the pins are aligned correctly Figure 3 Correct alignment of LPMBH 6 MP cable conne...

Page 13: ...rol is desired due to unusual viewing conditions such as severe reflections or flashing lights the IC LINK must send a manual Exposure command followed by direct Iris position commands The operator no...

Page 14: ...de all the time The one set of conditions which may force the operator to switch into Manual mode is when viewing a relatively close object that does not have much sharp detail This occurs because the...

Page 15: ...isconnect your cable from the camera Then turn on the power and measure the voltage at the camera end of the cable according to your camera s pinout If there is no voltage or low voltage then you have...

Page 16: ...cidental damage 5 3 CAMERA OPERATIONAL CHECKS Fuse F1 on the electronics interface board assembly should be checked for continuity F1 is a 1 25A 32VDC fuse element that protects the camera module from...

Page 17: ...O ring should be given a light coating of silicone grease or other O ring lubricant before re assembly On the internal camera assembly ensure that all electrical connectors are correctly fitted and al...

Page 18: ...52 51413 REV B 12 APPENDIX RS 485 CEX HD CAMERA DRAWINGS 52 51405 Top Assembly RS 485 CEX HD 52 51411 Installation RS 485 CEX HD 52 51412 Wiring Diagram RS 485 CEX HD...

Reviews: