10-00640   REV A 

6  CONNECTOR WIRING/CONFIGURATIONS 

 
NOTE: For 

DC Units 

4 Pins are required for RS-485 Lamps and 3 Pins are required for 

Analog Control Lamps. 
 
NOTE: For 

AC Units 

5 Pins are required for RS-485 and Analog Control Lamps 

 

 

CAUTION:   Do not apply power to RS-485 pins as it will damage the 
                      RS-485 driver electronics.

 

 

 

24 VDC

 

 

120 VAC 

RS485 (Except -04 

Configuration) 

Analog 

0-5 or 0-10VDC 

RS485 (-04 

Configuration) 

        None          

(Full on) 

RS485  

Analog  

0-5 or 0-10VDC   

Full on or 

Phase 

Control 

1 - DC Common 

1 - DC Common 

1 - +26VDC 

1 - DC Common  1 - Ground 

1 - Ground 

1 - Ground 

2 - +24 VDC 

2 - +24 VDC 

2 - 26VDC RET 

2 - +24 VDC 

2 - Load 

2 - Load 

2 - Load 

3 - RS 485 A 

3 - Analog Dimming Input 

3 - GND 

 

3 - Neutral 

3 - Neutral 

3 - Neutral 

4 - RS-485 B 

 

4 - N/C 

 

4 - RS 485 A 

4 - DC Common 

 

 

 

5 - RS485-B 

 

5 - RS-485 B 

5 - Analog Dimming Input 

 

 

 

6 - RS485-A 

 

 

 

 

 

 

7 - N/C 

 

 

 

 

Note:

 If a connector has more pins than is listed in the table above, all other pins that are not listed are not 

connected. 

Example:

 24 VDC, RS485 light with a 6 pin connector would be: 

  

1 - DC Common, 2 - +24 VDC, 3 - RS485 A, 4 - RS485 B, 5 - Not Connected, 6 - Not Connected. 

 

 

 

 

-01 MCBH-4-MP  

SS SUBCONN 

-02 LPMBH-4-MP 

BRASS IMPULSE 

-03 BH-4-MP 

BRASS SUBCONN 

-04 SEANET 101 

SS SCHILLING 

 

 

 

 

-07 5507-1503 

SS SEACON 

-09 LPBH-3-MP 

BRASS 

SUBCONN 

-10 BH-3-MP 

BRASS SUBCONN 

-12 MSAJ-3-BCR  

CRE SEACON 

Summary of Contents for ROS Lightning

Page 1: ...10 00640 REV A OPERATION AND MAINTENANCE MANUAL 5618 Copley Drive San Diego CA 92111 7902 TEL 858 565 8500 FAX 858 565 8808 www rosys com ROS Lightning...

Page 2: ...ORD 1 1 WARNINGS 2 2 DESCRIPTION 2 3 PART NUMBER CONFIGURATION 3 4 PRODUCT SPECIFICATIONS 2 4 1 GENERAL SPECIFICATIONS 2 4 2 LIGHT OUTPUT 3 5 INSTALLATION GENERAL FUNCTIONALITY 3 6 CONNECTOR WIRING CO...

Page 3: ...of the State of California shall govern this warranty In the event the defect is determined to be within the terms of this warranty then ROS agrees to repair and or replace at ROS discretion the prod...

Page 4: ...stance during installation and or operation of these products If you have any questions or problems with this product that are not covered by this manual or instruction please contact our agent in you...

Page 5: ...10 00640 REV A 1 CHANGE RECORD REV DESCRIPTION DATE X1 SEE EC 01258 12DEC12 A SEE EC 01564 15APR13...

Page 6: ...t to comfortably touch the Lightning with your bare hand 2 DESCRIPTION The ROS Lightning LED lamp is a revolutionary underwater LED lamp Its technology gives the end user the capability of having a la...

Page 7: ...R PHASE CONTROL IS NOT AVAILABLE WITH 24 VDC AL X X X X X X X X X N A X X 01 MCBH 4 MP SS SUBCONN 02 LPMBH 4 MP BRASS IMPULSE 03 BH 4 MP BRASS SUBCONN 04 SEANET 101 SS SCHILLING 07 5507 1503 SS SEACON...

Page 8: ...depending on external connector End of Life Light Output 70 Rated Intensity 50 000 Hrs Optical Color Temperature 6200 K Nominal Lumen Output Floodlight 10 000 Lumen Nominal Spotlight 8 000 Lumen Nomin...

Page 9: ...act your sales representative for any issues with your new LED lamp To install your new LED lamp use the bolt pattern provided on the back of the lamp or an available ROS mounting clamp Note that your...

Page 10: ...on 1 Ground 1 Ground 1 Ground 2 24 VDC 2 24 VDC 2 26VDC RET 2 24 VDC 2 Load 2 Load 2 Load 3 RS 485 A 3 Analog Dimming Input 3 GND 3 Neutral 3 Neutral 3 Neutral 4 RS 485 B 4 N C 4 RS 485 A 4 DC Common...

Page 11: ...ower on Not connected properly Check cables and power supply Check wiring Verify your have serial communication Verify proper input power Communication issues Not connected properly Verify RS 485 to R...