10-00609 REV D
6
10% of the maximum light output. When the internal temperature returns to the safe
operating range the light will return to full intensity. During this self regulating
temperature protection the MV-LED II will not respond to commands to increase light. If
the MV-LED II internal temperature reaches 63.5ºC it will reduce its intensity to 0% until
the temperature returns to the safe operating range.
Serial communication is still available while the MV-LED II RS485 is in temperature
protection mode.
The thermal protection is intended as a failsafe feature to protect the light from
unintentional damage from extended use in air. It is not recommended to intentionally
run the light out of water for any extended period as it will reduce the product lifespan.
4 CONNECTOR WIRING
NOTE: 4 Pins are required for RS-485 lamps and 3 pins are required for analog control
lamps.
CAUTION: Do not apply power to RS-485 pins as it will damage the RS-485
driver electronics.
RS-485
RS-485
Analog (0-5VDC,0-10VDC)
All Configurations BUT -04
-04 Configuration
All Configurations
1 - DC Common
2 - +24 VDC
3 - RS 485 A
4 - RS-485 B
1 - +26VDC
2
– 26VDC RET
3 - GND
4
– N/C
5
– RS485-B
6
– RS485-A
7
– N/C
1 - DC Common
2 - +24 VDC
3
– Analog Dimming Input
4
– Not Connected
-01 MCBH-4-MP
-02 LPMBH-4-MP
-03 BH-4-MP
-04 SEANET 101
-05 IESQ4M
-06 IERD2M-BC-4
-07 5507-1503
-08 XSG-3-BCL-HP-SS