8.3 Maintenance
After power failures always reset the table before use.
The frame is maintenance-free. Moving parts have been lubricated for life. For reasons of safety and
reliability we recommend inspection of the frame once a year:
-
Check that all bolts have been securely tightened.
-
Check that the table moves freely and without problems from bottom to top position.
-
Resetting the frame:
Press the DOWN button and adjust the frame to bottom position.Press
the DOWN button once more and keep it depressed for 5 sec. to reset the controlbox. Check
that the movement is smooth and even. Make sure that the mains cable moves freely.
-
Check that all cables have been mounted correctly and are undamaged..
Only use Ropox original spare parts for replacement. If other spare parts are used, the right to complain
may become void.
9. Fault finding
9.1 The table seems loose or unstable
The assembly screws have not been securely tightened.
Retighten all screws, cf. mounting instructions.
9.2 The frame cannot be adjusted in height (adjustment very difficult)
Check mains voltage to controlbox and that the power has been switched on..
Check cables and plug-in connections between controlbox and motor.
Check cable and plug-in connection between controlbox and hand control switch..
9.3 The frame does not move straight
If the frame does not move straight it must be reset. See Maintenance 8.3 ”Resetting”.
Inspections, service and repairs must be carried out by competent personnel