background image

 

 

© ROPOX 2015 

 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4SingleElectric 

User Manual 
Mounting Instructions 

Keep this folder with product at all times! 

 
 

PDF 6090 / Rev 001 

 

Summary of Contents for 4SingleElectric

Page 1: ... ROPOX 2015 4SingleElectric User Manual Mounting Instructions Keep this folder with product at all times PDF 6090 Rev 001 ...

Page 2: ...SAFETY STRIP 9 6 3 PERFORMANCE TEST 10 7 LIST OF COMPONENTS 11 8 OPTIONS 12 9 SAFETY IN USE 13 10 CLEANING MAINTENANCE 14 10 1 Cleaning of frame 14 10 2 Maintenance 14 10 3 Service schedule operation and maintenance 15 11 TROUBLE SHOOTING 15 11 1 The frame seems loose or unstable 15 11 2 The height of the frame cannot be adjusted adjustment seems very difficult 15 11 3 The frame does not move stra...

Page 3: ... will be considered a new unit Therefore the assembled product must be subjected to a risk assessment to obtain CE marking 3 Application 4Single is designed to obtain optimum working height for the user It is an activity table and should therefore not be used as a lifting table or person lifter The product must be used indoor under normal room temperatures and humidity as stated in section 4 4Sing...

Page 4: ... and various plastic components Surface treatment Blue chromate powder coating Standard CWS 81283 RAL 7021 mat Power supply 230VAC 2 5A 50Hz Standby primary 1 1W Control voltage 24VDC Duty circle Max 10 conform to 1 min active 9 min pause Max load of frame 150kg evenly distributed Speed lifting time Approx 32 mm sec approx 10sec Increased load of frame 250 kg evenly distributed option Speed liftin...

Page 5: ...hout middle support Table size with middle support Length 60cm 300cm Length 60cm 300cm Width 60cm 120cm Width 121cm 200cm Height 55 85cm H1 Height w wheels 6 5cm Height 65 95cm H2 For table top length 60 300cm Frame length always 0 4cm less than the table top i e 59 6 299 6cm Length 35cm Width 60 200cm Frame width always 0 4cm less than table top i e 59 6 199 6cm 16cm Width 6cm 33 6cm 6cm 6cm ...

Page 6: ...for control unit 50 40000 039 1 6 Leg 1 2 7 Leg 2 2 8 Allen screw M8x16 95010003 16 9 Side fascia profile Length frame width 12 4cm 2 10 Front fascia profile Length frame length 12 4cm 2 11 Screw ø4 8x13 Torx 95091012 6 12 Cover plates 50 40000 025 4 Black Red 7 10 4 11 8 9 1 12 3 3 6 2 13 Black Red Red Black Red Black Leg 1 Leg 1 Leg 2 Leg 2 5 Green by increased lifting power Green by increased l...

Page 7: ...petent personnel Prior to mounting check that all parts have been provided See list of components section 7 6 1 Assembly of frame 6 1 3 Mount the spring for retention of motor plug 6 1 1 Mount hexagonal shaft and motor cable 6 1 2 Mount motor on side fascia Free cut of profile away from table top ...

Page 8: ...a plane surface and mount legs See label on legs 6 1 5 Now mount the two front fascias Important Push side and front fascias firmly against the leg before retightening the fascias Tighten the bolts securely by means of the wrench provided 6 1 6 Position the angle plate for control unit as shown and fasten it to front fascia 6 1 7 Attach control unit to angle plate and fasten ...

Page 9: ...lace the frame on the table top and push the cover plates between legs and table top Centre the frame in relation to the table top 6 1 11 Connection to control unit 6 1 10 Mounting of fixed control switch Pull the cable through the front fascia and insert it into the control unit 6 2 1 Push the safety strip through all four legs and fit it on the underside of the fascia by means of the double adhe...

Page 10: ...2 Connect the motor cables to M1 and M2 3 Connect the control switch to HS 4 Press DOWN on the control switch move the frame to bottom position check that the movement is even and smooth Make sure that the hose connections follow the movement of the frame and that they do not get squeezed The frame is now reset 5 Press UP on the control switch move the frame to top position and check that the move...

Page 11: ...30VAC incl mains cable 300cm 1 pc Contained in control unit Control switch small press pad 3x6cm 30 67840 Control switch standard 1 pc Incl 150cm cable Adhesive plate 96000155 5 pcs Strips black 96000165 5 pcs Angle plate for control unit 50 40000 039 1 pc Motor 96000553 2 pcs Motor cable 96000573 2 pcs Allen screw M8x16 95010003 16 pcs Screw ø4 8x13 95091012 6 pcs Screw ø4 2x6 5 95090806 2 pcs Sp...

Page 12: ...e wheels grey 4 wheels 50 41600 Increase the table height by 7 5cm 1 set Increased lifting power set of legs H1 50 41320 Max load 250kg evenly distributed 1 set To be ordered with main order For frames with increased lifting power the gear housing will be green and black Increased lifting power set of legs H2 50 41420 Max load 250kg evenly distributed 1 set To be ordered with main order For frames...

Page 13: ...ly accessible locations where children or persons with reduced observation capability may get near the table the person operating the table must pay attention to those present in order to prevent dangerous situations Make sure that there is free space above and below the table to allow height adjustment Do not operate the table in case of defects or damage Do not overload the table and make sure t...

Page 14: ...ame to bottom position Press the DOWN button again and keep it pressed for 5 sec to reset the control unit Check that the movement is smooth and even Make sure that the mains cable moves freely Check that water connection hoses and draining hoses if available are tight and functional Check that cable to hotplate if available is undamaged and may move freely Check that all cables have been mounted ...

Page 15: ... been fitted there must be a short circuit plug on the safety strip cable See mounting instructions fig 6 2 2 If a safety strip has been fitted Check that the safety strip has not been activated Remove the short circuit plug from the safety strip to the Y cable of the control unit See mounting instructions fig 6 2 2 If the table works without connection of the safety strip the safety strip has bee...

Page 16: ...ge 16 ROPOX 2019 12 Complaints See General Terms of Sale and Delivery on www ropox com ROPOX A S Ringstedgade 221 DK 4700 Naestved Tel 45 55 75 05 00 Fax 45 55 75 05 50 E mail info ropox dk www ropox com ...

Reviews: