Device functions
Page 22
RES-5012
Version 2
HEAT
(yellow)
—
START requested but func-
tion blocked (e.g.
AUTOCAL active, set tem-
perature < 40 °C)
START executing
OUTPUT
(green)
In control mode, luminous intensity is proportional to heating current.
ALARM
(red)
Configuration error, no
AUTOCAL possible
Controller calibrated incor-
rectly, run AUTOCAL
Error,
section 8.19
ECAT RUN
(green)
Off
: Init
Blinks green at 2.5 Hz
: Pre-Operational
Single flash
: Safe-Operational
Operational
ECAT ERROR
(red)
Off
: no EtherCAT
®
communication error
Blinkts at 2.5 Hz
: illegal configuration. Master is not able
to change status
Single flash
: local error
Double flash
: Prozess data watchdog
—
L/A IN, OUT
(green)
—
EtherCAT
®
frames are
transmitted
Connection to the
EtherCAT
®
network
LED
Blinks slowly (1 Hz)
Blinks fast (4 Hz)
Lit continuously