Technical data
Page 92
RES-5009
Version 1
CAN interface
CAN interface CAN 2.0A as per ISO 11898
Baud rates:
10 kBaud; 20 kBaud; 50 kBaud; 100 kBaud, 125 kBaud;
205 kBaud; 250 kBaud; 500 kBaud; 800 kBaud; 1 MBaud
SUB-D9 connector as per CiA 303/1 specification
CAN protocol
CANopen protocol (as per CiA profile 301 in version 4.2.0)
ROPEX CAN protocol
Heating element type
and temperature
range
Apart from setting via the rotary encoder switch or the CAN interface, the setting
for the temperature range and temperature coefficient can be made through the
ROPEX visualisation software (
section 9.8 "USB interface for visualisation soft-
Temperature range:
200 °C, 300 °C, 400 °C or 500 °C
Temperature coefficient: 400…4000ppm/K (variable setting range)
Five areas can be set over rotary coding switches or CAN interface:
Temperature coefficient 1100ppm/K, 0…300°C (e. g. alloy A20)
Temperature coefficient 780ppm/K, 0…300 °C (e. g. alloy L)
Temperature coefficient 1100ppm/K, 0…500 °C (e. g. alloy A20)
Temperature coefficient 780ppm/K, 0…500°C (e. g. alloy L)
Temperature coefficient 3500ppm/K, 0…300°C
Please take the necessary setting from the ROPEX application report
Analogue output
(Actual value)
Terminals 17+7
0…10 VDC, I
max
= 5 mA
corresponding to 0…300°C or 0…500°C
Precision: ±1% plus 50 mV
Alarm relay
Terminals 12, 13, 14
U
max
= 30 V (DC/AC), I
max
= 0.2 A, changeover contact, voltage-free
Power loss
Max. 20 W
MTTF as per
ISO 13849-1
1522 years (see EN ISO 13849-1, table C.3, Triacs)
Ambient conditions
Maximum altitude 2000 m
Ambient temperature: +5…+45 °C
Maximum relative humidity: 80% at temperatures up to +31 °C, decreasing line-
arly to 50% relative humidity at +45 °C.
Degree of protection
IP 20
CAUTION
When the terminals are open, the screw must be screwed in to ensure
contact protection.