Device functions
Version 1
RES-5009
Page 45
A display instrument can be connected to this analogue output for visualisation of the heating element tempera-
ture.
The ROPEX temperature display ATR-x in its overall characteristics (size, scaling, dynamic behaviour) is optimally
suited for visualisation and can be used for this, if needed (
section 18 "How to order" on page 95).
The following criteria can be assessed or checked with the ROPEX temperature indicator ATR-x:
• TARGET-ACTUAL comparisons
• Heat up speed,
• Reaching the setpoint in the specified time
• Cooling of the heating element
• Faults in the control circuit (loose contacts, contacting and wiring problems)
• Network faults
• mutual interference of several neighbouring control circuits.
In case of alarm, this analogue output is used to output differentiated error messages (
9.7
Booster connection
The RESISTRON
®
Temperature Controller RES-5009 has a connection for an external switching amplifier
(booster) as standard. The connection of an external switching amplifier (at the terminals 15+7) is required at high
primary currents (constant current > 5 A, impulse current > 25 A). The switching amplifier must be connected in
accordance with section 7.7 "Wiring diagram with booster connection" on page 20.
CAUTION
In order to avoid the EMC interference, the connection cable to the external switching amplifier
may not exceed a length of 1 m and has to be twisted.
9.8
USB interface for visualisation software ROPEXvisual
®
A USB interface (type micro-USB) is available for system diagnosis and process visualisation. A data connection
can be built up with the ROPEX visualisation software ROPEXvisual
®
over this USB interface.
12 13 14 15 16 17 18
9
8
6
5
10
11
7
4
3
2
1
RES-5009
!
PROCESS CONTROL
EQUIPMENT
E464680
AC
OUTPUT
HEAT
ALARM
ERR
RUN
BUS POWER
24 V POWER
www.
.de
ROPEX
Made in Germany
Vi sual
CAN
RESISTRON
Summary of Contents for RESISTRON RES-5009