Technical data
Page 28
RES-401
Version 1
8
Technical data
Type of construction
Housing for installation in the electrical cabinet
Snaps onto a standard top hat rail (DIN TS35 rail, 35 mm) acc. to DIN EN 50022
Dimensions: 90 x 75mm; height: 135mm (incl. terminals)
Line voltage
All controllers manufactured as of October 2005:
115VAC version: 110VAC -15%…10% (equivalent to 94…132VAC)
230VAC version: 220VAC -15%…10% (equivalent to 187…264VAC)
400VAC version: 380VAC -15%…10% (equivalent to 323…456VAC)
All controllers manufactured as of January 2004 up to September 2005:
115VAC version: 115VAC -15%…10% (equivalent to 98…132VAC)
230VAC version: 230VAC -15%…10% (equivalent to 196…264VAC)
400VAC version: 400VAC -15%…10% (equivalent to 340…456VAC)
All controllers manufactured up to December 2003:
115VAC, 230VAC or 400VAC, tolerance: +10% / -15%
depending on version selected (
section 11 "How to order" on page 30)
Line frequency
47…63Hz, automatic adjustment to frequencies in this range
Heatsealing band
type and temperature
range
Temperature coefficient 1100ppm, 0…300°C (e.g. Alloy-A20)
Set point selection
Terminals 16+17
With an external PD-3 precision potentiometer (R = 2k
Ω
)
0…2k
Ω
, equivalent to 0…300°C
Analog output
(actual value)
Terminals 14+15
0…10VDC, Imax = 5mA
Equivalent to 0…300°C
Accuracy: ±1% add. 50mV
Digital logic levels
Terminals 8, 12, 13
LOW (0V): 0…2VDC
HIGH (24VDC): 12…30VDC (max. current input 6mA)
Reverse polarity-protected
Maximum load
(primary current of
impulse
transformer)
I
max
= 5A (duty cycle = 100%)
I
max
= 25A (duty cycle = 20%)
Power dissipation
max. 20W
Ambient
temperature
+5…+45°C
Degree of protection
IP20