Ropex RESISTRON RES-222 Replacement Instructions Manual Download Page 6

Page 6

Replacing RES-222/RES-440

Menu structure of the RES-440

1

Heatsealing temp.

22

Alloy/range

21

Factory settings

20

Language

Alarm

Autocal

7

Autocal?

6

Hold mode

5

Cooling value

4

Heatsealing time

3

Starting delay

2

Preheating temp.

Main menu

Power-up message

25

Set point exceeded

26

Time control

27

Cooling mode

29

Relay K1 function

30

Cycles

31

Alarm relay

32

Meas. impulse 

24

Set point reached

23

Max. temperature

Settings

Configuration

1)

2)

1) Time control ON
2) Time control OFF

1)

2)

28

Start of sealing time

Fault

MOD 1 only

Autocal

7

Autocal?

The relevant menu
steps are shown on
a gray background.

Summary of Contents for RESISTRON RES-222

Page 1: ... are described below In addition the differences between the controller types are explained These instructions provide only a brief overview of the two controllers If in doubt please refer to the latest version of the controller documentation which is always binding Comparison of RES 222 RES 440 Dimensions The front panel cutout dimensions of the RES 222 and RES 440 controllers are identical The R...

Page 2: ...entiometer the pointer of the indicating instrument must be set to Z RES 440 Automatic zero calibration AUTOCAL with step 7 in the software menu RES 222 Indicated by means of a red ALARM LED on the front panel Reset by pressing the RESET key RES 440 Indicated on the display The error is identified by a numeric code ª RES 440 documentation Reset by pressing the RESET key ENTER HAND RESET RES 222 Se...

Page 3: ...h off the line voltage and verify the safe isolation from the supply 2 Remove the existing RES 222 controller 3 The supply voltage specified on the nameplate of the RES 440 controller must be identical to the line voltage that is present in the plant or machine The line frequency is automatically detected by the temperature controller in the range from 47 to 63Hz 4 Set the DIP switches on the RES ...

Page 4: ...on by pressing 11 Set the function of relay K1 Press the key repeatedly until step 29 is displayed Select Relay K1 active if Tact Tset with the keys Confirm your selection by pressing Press the key for at least 2s to return to the main or Alarm menu 12 Calibrate the zero point Activate the AUTOCAL function while the heatsealing band is still cold Press the key repeatedly until step 7 is displayed ...

Page 5: ...Press the key for at least 2s to open the Configuration menu Step 20 is displayed Press the key repeatedly until step 24 is displayed Select the low switching threshold Set point reached with the keys Confirm your selection by pressing 15 Press the key once Step 25 is displayed Select the high switching threshold Set point exceeded with the keys Confirm your selection by pressing Press the key for...

Page 6: ... 3 Starting delay 2 Preheating temp Main menu Power up message 25 Set point exceeded 26 Time control 27 Cooling mode 29 Relay K1 function 30 Cycles 31 Alarm relay 32 Meas impulse 24 Set point reached 23 Max temperature Settings Configuration 1 2 1 Time control ON 2 Time control OFF 1 2 28 Start of sealing time Fault MOD 1 only Autocal 7 Autocal The relevant menu steps are shown on a gray backgroun...