Ropex RESISTRON RES-222 Replacement Instructions Manual Download Page 1

Industrie-Elektronik GmbH

Tel: +49/(0)7142/7776-0

E-Mail: 

[email protected]

Gansäcker 21

Fax: +49/(0)7142/7776-19

Internet: 

www.ropex.de

D-74321-Bietigheim-Bissingen

Data subject to change

7.

3.

03

RESISTRON

Replacing 

RES-222/RES-440

GB

Replacement

Instructions

The front panel dimensions and terminal assignment of
the RESISTRON RES-440 temperature controller are
compatible with those of the RES-222.
The steps that are necessary to migrate from
RES-222-0-3 or RES-222-0-5 (standard devices
without modifications) to RES-440 are described

below. In addition, the differences between the
controller types are explained.
These instructions provide only a brief overview of the
two controllers. If in doubt, please refer to the latest
version of the controller documentation, which is
always binding.

Comparison of RES-222 / RES-440

Dimensions

The front panel cutout dimensions of the RES-222 and
RES-440 controllers are identical. The RES-440

features a protective film to IP42 instead of the
transparent hood. A transparent front cover featuring
IP65 is available as a option.

Temperature indication (actual value)

RES-222

 

RES-440

 

RES-222

 

Indication on an analog instrument (ATR-3).

RES-440

 

Indication on the 4-line display
(dynamic bar and digital value).

Summary of Contents for RESISTRON RES-222

Page 1: ... are described below In addition the differences between the controller types are explained These instructions provide only a brief overview of the two controllers If in doubt please refer to the latest version of the controller documentation which is always binding Comparison of RES 222 RES 440 Dimensions The front panel cutout dimensions of the RES 222 and RES 440 controllers are identical The R...

Page 2: ...entiometer the pointer of the indicating instrument must be set to Z RES 440 Automatic zero calibration AUTOCAL with step 7 in the software menu RES 222 Indicated by means of a red ALARM LED on the front panel Reset by pressing the RESET key RES 440 Indicated on the display The error is identified by a numeric code ª RES 440 documentation Reset by pressing the RESET key ENTER HAND RESET RES 222 Se...

Page 3: ...h off the line voltage and verify the safe isolation from the supply 2 Remove the existing RES 222 controller 3 The supply voltage specified on the nameplate of the RES 440 controller must be identical to the line voltage that is present in the plant or machine The line frequency is automatically detected by the temperature controller in the range from 47 to 63Hz 4 Set the DIP switches on the RES ...

Page 4: ...on by pressing 11 Set the function of relay K1 Press the key repeatedly until step 29 is displayed Select Relay K1 active if Tact Tset with the keys Confirm your selection by pressing Press the key for at least 2s to return to the main or Alarm menu 12 Calibrate the zero point Activate the AUTOCAL function while the heatsealing band is still cold Press the key repeatedly until step 7 is displayed ...

Page 5: ...Press the key for at least 2s to open the Configuration menu Step 20 is displayed Press the key repeatedly until step 24 is displayed Select the low switching threshold Set point reached with the keys Confirm your selection by pressing 15 Press the key once Step 25 is displayed Select the high switching threshold Set point exceeded with the keys Confirm your selection by pressing Press the key for...

Page 6: ... 3 Starting delay 2 Preheating temp Main menu Power up message 25 Set point exceeded 26 Time control 27 Cooling mode 29 Relay K1 function 30 Cycles 31 Alarm relay 32 Meas impulse 24 Set point reached 23 Max temperature Settings Configuration 1 2 1 Time control ON 2 Time control OFF 1 2 28 Start of sealing time Fault MOD 1 only Autocal 7 Autocal The relevant menu steps are shown on a gray backgroun...

Reviews: