Startup and operation
Page 20
RES-445
4.
Temperature coefficient 570ppm, 0…300°C
(software revision 019 or higher)
5.
Temperature coefficient 630ppm, 0…300°C
(software revision 019 or higher)
6.
Temperature coefficient 700ppm, 0…300°C
(software revision 019 or higher)
7.
Temperature coefficient 780ppm, 0…200°C
(e.g. Alloy L, software revision 011 or higher)
8.
Temperature coefficient 780ppm, 0…300°C
(e.g. Alloy L, software revision 011 or higher)
9.
Temperature coefficient 780ppm, 0…400°C
(e.g. Alloy L, software revision 011 or higher)
10.
Temperature coefficient 780ppm, 0…500°C
(e.g. Alloy L, software revision 011 or higher)
11.
Temperature coefficient 870ppm, 0…300°C
(software revision 019 or higher)
12.
Temperature coefficient 980ppm, 0…300°C
(software revision 019 or higher)
13.
Temperature coefficient 1100ppm, 0…200°C
(e.g. Alloy-20)
14.
Temperature coefficient 1100ppm, 0…300°C
(•)
(e.g. Alloy-20)
15.
Temperature coefficient 1100ppm, 0…400°C
(e.g. Alloy-20)
16.
Temperature coefficient 1100ppm, 0…500°C
(e.g. Alloy-20)
17.
Temperature coefficient 3500ppm, 0…200°C
(e.g. NOREX)
18.
Temperature coefficient 3500ppm, 0…300°C
(e.g. NOREX)
9.3.5
Configuration of the timer function
The necessary controller settings are
explained in the detailed functional
descriptions in Kap. 10.5 „Menu steps“ auf Seite 28
and Kap. 10.19 „Time control (timer function)“ auf
Seite 42. They are only allowed to be entered by
technically trained persons.
The timer function is activated with step 26 in the
Configuration menu:
9.3.6
Relay K1 (without time control)
The function of relay K1 is specified with step 29 in the
Configuration menu:
The following settings are possible when time control is
deactivated:
1.
"Off"
(••)
Relay K1 has no function
2.
"Active if Tact = Tset"
Relay K1 is switched according to the
"Temperature OK" signal. This relay thus has the
same function as the output at terminals 20+21
(
!
Kap. 10.12 „"Temperature OK" signal“ auf
Seite 38).
Other settings are available in this menu when time
control (timer function) is active. They are described in
Kap. 10.19.7 „Relay K1 (with time control)“ auf
Seite 45.
9.3.7
Configuration of the alarm relay
The alarm relay is set with step 31 in the Configuration
menu:
There are two possible settings:
1.
"Normal"
Alarm relay contact closed by alarm
2.
"Inverse"
Alarm relay contact opened by alarm
9.4
Heatsealing band
9.4.1
General
The heatsealing band is a key component in the control
loop, since it is both a heating element and a sensor.
The geometry of the heatsealing band is too complex to
(•) Factory setting
!
(••)Factory setting