Technical data 

 

 

Version 1 

PEX-W5 

Page 5 

3 Technical 

data 

 

PEX-W5 

Design 

Housing for electrical cabinet mounting on a TS35 top hat rail 
in accordance with DIN EN 50022 

Dimensions 

Width: 55.6 mm 

Height: 64.5 mm 

Depth: 108.5 mm 

Weight 

0.18 kg including the plug-in connector part 

Housing material 

Plastic, polycarbonate, UL-90-V0 

UL file 

E464680 

Mounting 

When mounting the device, a clearance of 20 mm to other 
devices is recommended. 

When mounting multiple current transformers, no clearance is 
required between the transformers. 

For mounting on a horizontal hat rail, the clip must face 
downward. 

For mounting on a vertical hat rail, end holders are necessary 
to mechanically fix the device. 

Degree of protection 

IP 20 

Ambient conditions: 

Max. altitude 2000 m 

Ambient temperature: +5°C to 45°C 

Max. relative humidity: 80% at temperatures up to 31°C, 
decreasing linearly to 50% at 45°C

 

Connecting cable 

Rigid or flexible cables are suitable 

Cross-section: 0.2 to 1.5 mm² (AWG 24…16) via the plug-in 
connector 

Connector: Tightening torque 0.5 to 0.6 Nm 

Tool: Screwdriver SZS 0.6x3.5 mm 

Note: 

If ferrules are used, they must be crimped in accordance with 
DIN 46228 or IEC/EN 60947-1 to ensure proper electrical 
contact.

 

Measuring range 

Measuring current I

R

 = 500 A (peak current) 

The continuous current is limited by the cable. 

Power loss 

Maximum 2.0 W (average) 

 

 

Summary of Contents for PEX-W5

Page 1: ...rature controller and is a part of the primary controlled impulse temperature control system Storage of the operating instructions Please read the operating instructions carefully before using the current transformer Retain the operating instructions for future reference and ensure that important information and functions are available to the user Copyright 2019 All contents in particular texts ph...

Page 2: ...ze the safety or the malfunction of the control loop This is the responsibility of the user Hazard classes The table below shows the dangers and possible consequences of the keywords in the operating instructions Keyword Definition Consequences for DANGER Imminent danger High level of risk that can result in death or serious injury People WARNING Possible dangerous situation Medium level of risk t...

Page 3: ...12 19 EU on the reduction of the increasing amount of electrical waste the aim of which is to reduce waste from electrical and electronic equipment and to dispose of it in an environmentally sound manner INFORMATION This device must not be disposed of in the residual waste To ensure material recycling or proper disposal place the device in the designated municipal collection point and observe the ...

Page 4: ...e cannot be routed through the opening a high current bar must be ordered see chapter 3 how to order The green connection terminal is intended for the measuring line IR to the temperature controller NOTE The general connection of the current transformer to the control system can be found in the corresponding controller documentation Please note the connection in individual cases according to the R...

Page 5: ... clip must face downward For mounting on a vertical hat rail end holders are necessary to mechanically fix the device Degree of protection IP 20 Ambient conditions Max altitude 2000 m Ambient temperature 5 C to 45 C Max relative humidity 80 at temperatures up to 31 C decreasing linearly to 50 at 45 C Connecting cable Rigid or flexible cables are suitable Cross section 0 2 to 1 5 mm AWG 24 16 via t...

Page 6: ...How to order Page 6 PEX W5 Version 1 4 How to order Current transformer PEX W5 Article number 885107 High current bar HCB article number 885110 ...

Reviews: