Roper FGS326RD Installation Instructions Manual Download Page 8

8

Typical flexible connection

1. Apply pipe-joint compound made for use with LP gas to the 

smaller thread ends of the flexible connector adapters (see B 
and G in following illustration). 

2. Attach one adapter to the gas pressure regulator and the 

other adapter to the gas shutoff valve. Tighten both adapters.

3. Use a 

¹⁵⁄₁₆

" combination wrench and channel lock pliers to 

attach the flexible connector to the adapters. Check that 
connector is not kinked.   

Complete Connection

1. Check that the gas pressure regulator shutoff valve is in the 

“on” position.

2. Open the manual shutoff valve in the gas supply line. The 

valve is open when the handle is parallel to the gas pipe.

3. Test all connections by brushing on an approved 

noncorrosive leak-detection solution. Bubbles will show a 
leak. Correct any leak found.

4. Remove cooktop burner caps and grates from parts 

package. Burner caps should be level when properly 
positioned. If burner caps are not properly positioned, 
surface burners will not light. Place burner grates over 
burners and caps.

5. Plug into a grounded 3 prong outlet.

Electronic Ignition System

Initial lighting and gas flame adjustments

Cooktop and oven burners use electronic igniters in place of 
standing pilots. When the cooktop control knob is turned to the 
“LITE” position, the system creates a spark to light the burner. 
This sparking continues, as long as the control knob is turned to 
“LITE.”

When the oven control is turned to the desired setting, sparking 
occurs and ignites the gas.

Check Operation of Cooktop Burners

Standard Surface Burners

Push in and turn each control knob to the “LITE” position. 

The flame should light within 4 seconds. The first time a burner is 
lighted it may take longer that 4 seconds to light because of air in 
the gas line. 

If burners do not light properly:

Turn cooktop control knob to the “OFF” position. 

Check that the range is plugged in and the circuit breaker has 
not tripped or the fuse blown. 

Check that the gas shutoff valves are set to the “open” 
position. 

Check that burner caps are properly positioned on burner 
bases.

Repeat start-up. If a burner does not light at this point, contact 
your dealer or authorized service company for assistance.

A. Gas pressure regulator
B. Use pipe-joint compound

C. Adapter (must have ½" male 

pipe thread)

D. Flexible connector

E. Manual gas shutoff valve

F. ½" or ¾" gas pipe

G. Use pipe-joint compound

H. Adapter

A. Gas pressure regulator shutoff valve

A. Closed valve
B. Open valve

A

B

C

D

E

F

G

H

A

A

A. Burner base
B. Burner cap

C. Burner grate

A

B

C

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

Summary of Contents for FGS326RD

Page 1: ...what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards tha...

Page 2: ...uilding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Clear the room building or area of all occupants In the State of Massachusetts the following installation instructions apply Ins...

Page 3: ...trical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section Contact a qualified floor covering installer to check that the floor covering can withstand at least 200 F 93 C Use an insulated pad or 0 64 cm plywood under range if installing range over carpeting IMPORTANT Some cabinet and building materials are not de...

Page 4: ...MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this range be provided Electronic ignition systems operate within wide voltage limits but proper grounding and polarity are necessary Che...

Page 5: ...e connector may be used for connecting range to the gas supply line A 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the range Rigid pipe connection The rigid pipe connection requires a combination of pipe fittings to obtain an in line connection to the range Th...

Page 6: ...d or hardboard in front of range Using 2 or more people stand range back up onto cardboard or hardboard InstallAnti TipBracket Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type of floor covering Before moving range slide range onto shipping base cardboard or hardboard 1 Remove template from the anti tip bracket kit found inside the ov...

Page 7: ... bracket 5 If installing the range in a mobile home you must secure the range to the floor Any method of securing the range is adequate as long as it conforms to the standards in the Location Requirements section LevelRange Place rack in oven Place level on rack first side to side then front to back If range is not level pull range forward until rear leveling leg is removed from the anti tip brack...

Page 8: ...osition the system creates a spark to light the burner This sparking continues as long as the control knob is turned to LITE When the oven control is turned to the desired setting sparking occurs and ignites the gas Check Operation of Cooktop Burners Standard Surface Burners Push in and turn each control knob to the LITE position The flame should light within 4 seconds The first time a burner is l...

Page 9: ... flame spreader and pull forward to remove tabs from rear of oven Using a mirror Insert a mirror to one side of the burner Look into the mirror to check flame 4 Push the BAKE pad 5 Press the START pad The oven bake burner should light within 8 seconds under certain conditions it may take the burner up to 50 to 60 seconds to light Electronic igniters are used to light the bake and broil burners Ref...

Page 10: ...nstalled If there is an extra part go back through the steps to see which step was skipped 2 Check to be sure you have all of your tools 3 Dispose of recycle all packaging materials 4 Check to be sure the range is level See Level Range 5 Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused by protective shipping material Dry thoroughly with a soft cloth For ...

Page 11: ...emove the burner base NOTE Reinstall one of the screws through the range cooktop to hold the orifice spud holder in place while removing and replacing the orifice spuds A To range B Manual shutoff valve closed position C Gas supply line WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have...

Page 12: ...he burner base using both screw 7 Replace burner cap 8 Repeat steps 1 7 for the remaining burners To Convert Oven Bake Burner 1 Remove oven racks 2 Use a combination wrench to turn the orifice hood down snug onto pin about 2 to 2 turns IMPORTANT Do not overtighten The oven bake burner flame cannot be properly adjusted if this conversion is not made See Adjust Oven Bake Burner Flame section To Conv...

Page 13: ... an access cover must be removed from the gas pressure regulator IMPORTANT Do not remove the gas pressure regulator Gas pressure regulator 3 Remove plastic cover from gas pressure regulator cap 4 Turn gas pressure regulator cap counterclockwise with a combination wrench to remove NOTE Do not remove the spring beneath the cap 5 Turn over the gas pressure regulator cap and reinstall on regulator so ...

Page 14: ... loosen the orifice hood away from the pin about 2 to 2 turns The oven broil burner flame cannot be properly adjusted if this conversion is not made See Adjust Oven Broil Burner Flame section ReplaceOvenRacks Storageor WarmingDrawer Replace oven racks in oven cavity Insert storage drawer or warming drawer into slide rails on sides of drawer opening Lift front of drawer slightly and push firmly to ...

Page 15: ...15 Notes ...

Page 16: ...TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge 9758657 2005 All rights reserved 3 05 Printed in U S A ...