The System cabinet comes with LED lighting, which is controlled via an IR sensor

located on the underside of the product.  The lighting can be controlled as detailed 

below: 

Turn Mirror ON/OFF

To turn the product on/off, slowly 
wave your hand in front of the IR 
sensor.

Operating Instructions

Change LED colour

1. When the product is OFF
2. Hold your hand in front of the 
IR sensor to adjust the colour 
temperature. 
3. Remove hand from IR sensor 
once desired colour temperature 
is achieved. 

Note: When the cabinet is 

switched on/off the colour 

temperature will be memorised.

Warm

White

2700K

Daylight

White

6000K

Natural

White

4000K

Change LED intensity

1. When the product is ON

2. Hold your hand in front of IR 

sensor tp adjust the brightness.

3. Remove hand from the IR 

sensor once desired brightness 

reached. 

Note: When the cabinet is 

switched on/off the brightness 

will be memorised.

<10%

100%

Hold hand 
in position

DO NOT connect
to a plug & socket outlet.

WIRING DIAGRAM - MAINS SUPPLY

COLOUR CODING:

L  -  Live 

= Brown

N  -  Neutral  = Blue
 

-  Earth  = Green & Yellow

2

2

2

OUTSIDE

ZONES

2

ZONE

1

0.75m

2.25m

3.0m

0.6m

0.6m

0.75m

IEE Bathroom Zones Diagram

Distances from a bath tub or shower tray

Bathroom fittings are subject to the appropriate zones in accordance with IEE 

Regulations. This product is 

only 

suitable for permanent indoor installation in Zone 2 

and outside zones. (See above). This product is 

not 

suitable for installation in Zone 0 

or 1, saunas, steam rooms or shower cubicles. Do

 not

 connect to a trailing plug and 

socket. Do 

not

 install onto surfaces that are either damp or electrically conductive.

Bathroom Zones

Electrical Safety

Suitable for UK Installations 

only

.

All fittings must be installed by a competent person, in accordance with current IEE 

wiring regulations. If in doubt consult a qualified electrician.

Important: 

Always switch off the electrical supply at the mains before installation and 

maintenance. It is recommended that the fuse is withdrawn or the circuit breaker is 

switched off for the necessary circuit before installation commences.

This product is manufactured to class I category and 

must 

have an earth connection.

Hold hand 
in position

Summary of Contents for SYC050

Page 1: ...er care service For any further assistance please feel free to contact our tech support team at techsupport roperrhodes co uk 10 Year Guarantee We have complete confidence in this Roper Rhodes bathroom cabinet and as such it is offered with a 10 year guarantee against defects in manufacture The guarantee requires that this product be used in the manner for which it was intended and that it is inst...

Page 2: ... SUPPLY COLOUR CODING L Live Brown N Neutral Blue Earth Green Yellow 2 2 2 OUTSIDE ZONES 2 ZONE 1 0 75m 2 2 5m 3 0 m 0 6m 0 6m 0 75m IEE Bathroom Zones Diagram Distances from a bath tub or shower tray Bathroom fittings are subject to the appropriate zones in accordance with IEE Regulations This product is only suitable for permanent indoor installation in Zone 2 and outside zones See above This pr...

Page 3: ...oint and parallel with the floor 1 4 Align the outer edge of the wall brackets with the ends of this line X 1 5 Using the wall brackets as a guide mark the hole positions 1 6 Drill the marked holes and fit the wall plugs 1 7 Screw the wall brackets into place ensuring the screws are fully tightened but take care not to overtighten Installation Procedure C D D C 1 1 Top of cabinet 25mm Centre Line ...

Page 4: ...mended that the fuse is withdrawn or the circuit breaker is switched off for the necessary circuit 2 1 Connect to mains electrical supply Connections should be made in accord ance with the latest IEE regulations This cabinet is manufactured to CLASS 1 and requires an earth connection Step 3 Finishing the installation 3 1 Hang the cabinet on the wall brackets as shown in 1 8 Ensure the wall bracket...

Reviews: