Please retain for future reference. Instructions should be kept / passed to end-user once installation is complete.

INSTALLATION & AFTERCARE INSTRUCTIONS

LED CABINET PRODUCT INSTRUCTIONS

PLATEAU & SUMMIT CABINET

 - 

AS515ALIL, AS615ALIL

ELECTRICAL SAFETY INSTRUCTIONS

All fittings must be installed by a competent person, in accordance with current IEE wiring regulations.  
If in doubt consult a qualified electrician

IMPORTANT

Always switch off the electrical supply at the mains during installation and maintenance. It is recommended 
that the fuse is withdrawn or the circuit breaker is switched off for the necessary circuit before installation 
commences.

The product must be installed with a minimum distance of 150mm between the infrared sensor and any 
adjacent wall or obstruction to ensure correct function of the sensor.

Fitting in Bathrooms is subject to the appropriate zone in accordance with IEE Regulations. This product is 
suitable for zone 2 and outside zones. 

IT IS NOT 

suitable for installation in Zone 0 or Zone 1. It is also not 

suitable for installation in saunas, steam rooms or shower cubicles. This product is only suitable for permanent 
installation. 

DO NOT 

connect to a trailing plug and socket outlet. Although this product has an Ingress 

Protection rating of IP44 it is only suitable for indoor use. Do not attach the product to surfaces that are damp 
or otherwise electrically conductive.

INSTALLATION CARE & SAFETY

Wear suitable eye protection when drilling. Take care when using power tools near water - the use of a residual 
current device (RCD) is advised. Beware of hidden cables or pipes. Take care if drilling on tiled surfaces in 
case the drill slips. A piece of masking tape applied to the wall before marking out the fixing holes will stop the 
drill from wandering.

DO NOT 

strike glass components with hard or pointed items. 

DO NOT

 place very hot or very cold items 

against or in close proximity to glass surfaces unless an adequately thick insulation material is used to prevent 
such items coming in contact with the glass.  

The nominal thickness of the mirror glass used in this product is 5mm and is film backed for safety.  If the glass 
becomes chipped or broken replace immediately.

This product should be positioned well away from curtains and other fabrics. Never cover the mirror. This 
product is heated, we recommend that it is turned off after use and should never be left on for prolonged 
periods of time 

This product could be dangerous and is only to be installed by a competent person.

CLEANING

It is recommended that the unit is cleaned with a soft, dry, non abrasive cloth when turned off.  Never use 
cleaning agents or abrasive materials on any type of surface finish.  Do not allow moisture to come into contact 
with the electrical components.

COMPLIANCE

This product complies with all relevant British 
and European safety standards.

2

2

2

OUTSIDE

ZONES

2

ZONE

1

0.75m

2.25m

3.0m

0.6m

0.6m

0.75m

BATHROOM ZONES DIAGRAM

Distances from a bath tub or shower tray

Summit - AS615ALIL

AO.011.18.V2

The product must be installed with a 
minimum distance of 150mm between 
the infrared sensor and any adjacent 
obstruction to ensure correct function 
of the sensor (see diagram).

MIN

150mm

Plateau - AS515ALIL

Reviews: