Please retain for future reference. Instructions should be kept / passed to end-user once installation is complete.
INSTALLATION & AFTERCARE INSTRUCTIONS
LED CABINET PRODUCT INSTRUCTIONS
PLATEAU & SUMMIT CABINET
-
AS515ALIL, AS615ALIL
ELECTRICAL SAFETY INSTRUCTIONS
All fittings must be installed by a competent person, in accordance with current IEE wiring regulations.
If in doubt consult a qualified electrician
IMPORTANT
Always switch off the electrical supply at the mains during installation and maintenance. It is recommended
that the fuse is withdrawn or the circuit breaker is switched off for the necessary circuit before installation
commences.
The product must be installed with a minimum distance of 150mm between the infrared sensor and any
adjacent wall or obstruction to ensure correct function of the sensor.
Fitting in Bathrooms is subject to the appropriate zone in accordance with IEE Regulations. This product is
suitable for zone 2 and outside zones.
IT IS NOT
suitable for installation in Zone 0 or Zone 1. It is also not
suitable for installation in saunas, steam rooms or shower cubicles. This product is only suitable for permanent
installation.
DO NOT
connect to a trailing plug and socket outlet. Although this product has an Ingress
Protection rating of IP44 it is only suitable for indoor use. Do not attach the product to surfaces that are damp
or otherwise electrically conductive.
INSTALLATION CARE & SAFETY
Wear suitable eye protection when drilling. Take care when using power tools near water - the use of a residual
current device (RCD) is advised. Beware of hidden cables or pipes. Take care if drilling on tiled surfaces in
case the drill slips. A piece of masking tape applied to the wall before marking out the fixing holes will stop the
drill from wandering.
DO NOT
strike glass components with hard or pointed items.
DO NOT
place very hot or very cold items
against or in close proximity to glass surfaces unless an adequately thick insulation material is used to prevent
such items coming in contact with the glass.
The nominal thickness of the mirror glass used in this product is 5mm and is film backed for safety. If the glass
becomes chipped or broken replace immediately.
This product should be positioned well away from curtains and other fabrics. Never cover the mirror. This
product is heated, we recommend that it is turned off after use and should never be left on for prolonged
periods of time
This product could be dangerous and is only to be installed by a competent person.
CLEANING
It is recommended that the unit is cleaned with a soft, dry, non abrasive cloth when turned off. Never use
cleaning agents or abrasive materials on any type of surface finish. Do not allow moisture to come into contact
with the electrical components.
COMPLIANCE
This product complies with all relevant British
and European safety standards.
2
2
2
OUTSIDE
ZONES
2
ZONE
1
0.75m
2.25m
3.0m
0.6m
0.6m
0.75m
BATHROOM ZONES DIAGRAM
Distances from a bath tub or shower tray
Summit - AS615ALIL
AO.011.18.V2
The product must be installed with a
minimum distance of 150mm between
the infrared sensor and any adjacent
obstruction to ensure correct function
of the sensor (see diagram).
MIN
150mm
Plateau - AS515ALIL