17
RootsScrub E430
The electrical equipment of the machine uses a mains voltage of
230 V/50 Hz AC. Easy access to brush motor and suction turbine
is possible after the upper part of the unit has been titled to
upside. The suction turbine has been provided with a fuse (E)
having a rating of T4A. It must be replaced by a fuse of same
rating (T stands for Time -lag). The brush motor is protected by a
circuit breaker (F) which requires to be manually reset incase of
tripping. When brush motor trips identify the cause and correct
it before trying to run the machine. The protector can be reset by
pressing transparent dome on the electrical box cover. Please
allow approximately 30 seconds before resetting.
Ÿ
If there should be repeated cases of failure, look for
the reason.
Ÿ
Any work at the electrical system has to be carried
out by specialized electricians only.
Compliance with our recommendations concerning
maintenance work will give you the certitude always having a
machine at your disposal, which is ready to work and in good
operating condition.
Please contact your local Roots Multiclean distributor; the
people there will be glad to perform that work for you. There
well trained personnel and genuine Roots spare parts are at your
disposal.
Ÿ
Well trained personnel and genuine Roots spare parts are at
your disposal.
Ÿ
In case of any inquiries or orders for spare parts, please
always quote the machine's serial number mentioned on the
nameplate.
Ÿ
The name plate is fixed in the rear side of the machine.
Ÿ
When cleaning or servicing the machine, and when
replacing any parts, shut off the machine and on principle
disconnect the power plug from the power supply.
Ÿ
For reasons of safety during cleaning and/or maintenance
work in or on the tank, the tank lid - when lifted - must be
secured so as to prevent accidental closing or tilting down.
Ÿ
The machine may be taken into operation
only if all guarding devices are fitted and in
protective position. As far as possible,
cleaning should not be done by hand, but
using appropriate tools or equipment.
Ÿ
Maintenance and repair work may be carried out only by
means of suitable tools and by the people trained in the
factory. For reasons of safety, only genuine spare parts may
be used.
Electrical system
Maintenance Schedule
Maintenance work
E. Fuse for vacuum motor.
F. Overload protector for
brush motor.
E
F
Daily
50
100
200
Check connection - extension
cables and plugs for good
condition; discard defective
cables immedietely
Empty and clean the soiled
water tank
Check the sealing strips of
squeegee for good condition
Check the squeegee for
possibly collected foreign
matter and clean it, if required
Check the float for proper
operation
Check the stainer in the fresh
water tank, clean it as
required.
Check the suction hose
between squeegee and soiled
water tank
Check the caps both of fresh
and soiled water drain hose;
chek them for smooth
operation
Check the squeegee sealing
strips for wear; renew them if
required
Check the brush for tight fit
and wear; renew them if
required
Check the tank lid seal; renew
if it is required
Check the fresh water infeed
to the brush
Remove carbon dust from the
suction motor, check the
carbon brush for smooth
operation and wear; renew as
required
Service Hours Every
Maintenance Work
MAINTENANCE
Summary of Contents for RootsScrub E430
Page 2: ...2 RootsScrub E430...
Page 18: ...18 RootsScrub E430...