6. Care
The battery must be kept clean and dry to prevent
creeping current. Any liquid in the battery container must
be extracted and disposed of according to regulations.
Distilled water level shall be maintained at safe level.
( refer battery manual )
7. Storage
If batteries are out of operation for longer periods, they
should be stored in fully charged state in a dry, frost free
room.
In order to ensure that the battery is ready for operation
at any time, full recharge every three months. When a
consumer is connected up (e.g. measuring or
controlling devices), it may be necessary to recharge
the battery every two weeks.
8. Faults
The customer service should be called immediately
when any faults are discovered in battery or battery
charger.
BATTERY INSTRUCTIONS
1.
Kindly ensure that the Warranty certificate of the
battery is available at your end.
Ÿ
Kindly read the Do’s & Don't’s of the battery,
understand and follow.
Ÿ
Check the electrolyte level before charging and top it
up with battery grade distilled water if required.
Ÿ
Match the battery to the correct charger.
Ÿ
Keep the battery well ventilated while charging.
Ÿ
Charge the battery immediately after it is
discharged.
Ÿ
Keep all inter cell connections and bolted terminals
tight and covered with petroleum jelly.
Ÿ
Keep the machine tank opened while charging to
improve ventilation.
Battery and Charger
Batteries connecting diagram
Ÿ
The batteries and charger are located in the fresh
water tank.
Ÿ
The on board charger is located in the fresh water
tank, mounted on to a special bracket.
AGM
LA
Lead Acid (LA) Battery Instructions:
3. Temperature
The battery temperature of 30 °C is rated temperature.
Higher temperatures shorten the service life and lower
temperatures reduce available capacity. 45 °C is the
limit temperature and is not tolerable as operating
temperature.
4. Electrolyte
The electrolyte is sulphuric acid (LA) stored in liquid
form. The specific gravity of the electrolyte and quantity
shall be checked weekly.
If the quantity is low, refill with battery grade distilled
water.
5. Maintenance
Daily maintenance-
Recharge the battery every time it
has been discharged.
Weekly maintenance-
Visual inspection after recharging
for signs of dirt and mechanical damage.
Maintenance to be carried out every three months
After fully recharging and following a standing period of
at least 5 hours, the following must be measured and
Recorded: – total voltage / – individual voltage
If noticeable changes are detected compared to
previous measurements, or differences between the
cells or block batteries, the customer service should be
called for testing or repair.