6. Care

The  battery  must  be  kept  clean  and  dry  to  prevent 
creeping current. Any liquid in the battery container must 
be extracted and disposed of according to regulations.
Distilled water level shall be maintained at safe level. 
( refer battery manual )

7. Storage

If batteries are out of operation for longer periods, they 
should be stored in fully charged state in a dry, frost free 
room.
In order to ensure that the battery is ready for operation 
at any time, full recharge every three months. When a 
consumer  is  connected  up  (e.g.  measuring  or 
controlling  devices),  it  may  be  necessary  to  recharge 
the battery every two weeks.

8. Faults

The  customer  service  should  be  called  immediately 
when  any  faults  are  discovered  in  battery  or  battery 
charger.

BATTERY INSTRUCTIONS

1. 

Kindly  ensure  that  the  Warranty  certificate  of  the 

battery is available at your end.

Ÿ

Kindly  read  the  Do’s  &  Don't’s  of  the  battery, 
understand and follow.

Ÿ

Check the electrolyte level before charging and top it 

up with battery grade distilled water if required.

Ÿ

Match the battery to the correct charger.

Ÿ

Keep the battery well ventilated while charging.

Ÿ

Charge  the  battery  immediately  after  it  is 
discharged.

Ÿ

Keep all inter cell connections and bolted terminals 
tight and covered with petroleum jelly. 

Ÿ

Keep  the  machine  tank  opened  while  charging  to 

improve ventilation.

Battery and Charger

Batteries connecting diagram

Ÿ

The batteries and charger are located in the fresh 

water tank.

Ÿ

The on board charger is located in the fresh water 

tank, mounted on to a special bracket.

AGM

LA

Lead Acid (LA) Battery Instructions:

3. Temperature

The battery temperature of 30 °C is rated temperature. 
Higher temperatures shorten the service life and lower 
temperatures  reduce  available  capacity.  45  °C  is  the 
limit  temperature  and  is  not  tolerable  as  operating 
temperature.

4. Electrolyte

The  electrolyte  is  sulphuric  acid  (LA)  stored  in  liquid 
form. The specific gravity of the electrolyte and quantity 
shall be checked weekly.
If  the  quantity  is  low,  refill  with  battery  grade  distilled 
water.

5. Maintenance

Daily maintenance- 

Recharge the battery every time it 

has been discharged.

Weekly maintenance- 

Visual inspection after recharging 

for signs of dirt and mechanical damage.
Maintenance to be carried out every three months

After fully recharging and following a standing period of 
at least 5 hours, the following must be measured and 
Recorded:  – total voltage / – individual voltage

If  noticeable  changes  are  detected  compared  to 
previous  measurements,  or  differences  between  the 
cells or block batteries, the customer service should be 
called for testing or repair.

B1

B2

Summary of Contents for RootsScrub B6050

Page 1: ...rub B6050 B6050C Dom Exp RootsScrub B6050 B6050C Walk Behind Floor Scrubber Drier Battery Read this manual completely and understand the instructionsbeforeoperatingthemachine EnglishVersion Owner s Ma...

Page 2: ...2 RootsScrub B6050 B6050C Dom Exp...

Page 3: ...Instructions First Operation Operation Brush Operation Squeegee Procedure for Scrubbing Maintenance Battery Instructions 4 5 5 6 8 12 13 14 16 18 Description Page No Roots Multiclean Ltd RMCL is not...

Page 4: ...r the product sold within India If the product requires repair or maintenance work to be performed please ensure that you get the machine serviced from an authorised service center or dealer of RMCL t...

Page 5: ...h 12 96 12 96 Airflow rate L sec 28 28 28 Vacuum Pressure mm of H2O 1087 1087 1087 Power Supply V 24 24 24 Total Power W 1000 1000 1000 Brush Motor W 720 650 720 Vacuum Motor power W A 420 18 420 18 4...

Page 6: ...r s manual Protect the machine from frost or extremely low temperatures Never vacuum up explosive liquids combustible explosive dusts as well as acids and solvents This includes diesel petrol kerosene...

Page 7: ...re that there is adequate ventilation for diverting the exhaust gases dust when operating the machine in a closed area Do not place hand or any object while the brushes are running Suitable tools must...

Page 8: ...ty water is drawn during the same cycle through the squeegee Thus the floor can be walked on immediately after it is dry and clean 2 3 4 1 Useful Tips Prior to wet cleaning it is necessary to sweep th...

Page 9: ...ts position with a help of a rope assy Care should be taken while closing the tank Do not drop hardly which might cause possible damage to equipment and cause personal injury This machine is not suita...

Page 10: ...pe when switched On while booting 0016 10 2 On Start Up On start up it displays the total previously run hours of the machine Format hhhh mm and battery voltage tower 0016 10 3 Brush Motor ON Abrush s...

Page 11: ...s 0016 10 6 The brush motor suction turbine icons will start flashing just before the battery cut off level 0016 10 7 For B 6050x B6050Cx Solenoid valve ON A tap symbol is displayed when the solenoid...

Page 12: ...tank should be empty Lift the squeegee Place the brush in front of the machine Raise the brush head Move the brush to center of the brush head Lower the brush head so that the catch is centered in the...

Page 13: ...g strips 2 Mount the new sealing strips by inverse sequence of operation Removal of Squeegee 1 Squeegee 2 Squeegee Knob 3 Squeegee Bracket group Mounting of Squeegee first time Lift squeegee bracket g...

Page 14: ...hines low foaming in order to preclude damages at the suction turbine We recommend our agents for cleaning and care which are perfectly adopted to the machine How to operate the machine Lever to adjus...

Page 15: ...re for draining tanks Unclamp the drain hose from the hose clamp Lower the tip of the drain hose to the floor level After draining the water completely clamp the hose in the hose clamp Cleaning of flo...

Page 16: ...ive you the certitude always having a machine at your disposal which is ready to work and in good operating condition Daily Every 50 Every 100 Every 200 Check connection extension cables and plugs for...

Page 17: ...ery Loose battery cable Tighten loose cable Main fuse blown Replace the fuse Main fuse blown Replace the fuse Faulty brush motor or loose cable Contact service Suction turbine does not work Faulty suc...

Page 18: ...ventilated area Make sure to connect the charger to the specified voltage and frequency Ensure that the seat cover is completely open Do not place any objects on the battery Electrolyte is highly cor...

Page 19: ...cell connections and bolted terminals tight and covered with petroleum jelly Keep the machine tank opened while charging to improve ventilation Battery and Charger Batteries connecting diagram The bat...

Page 20: ...tions Type Off Board Rating 30 Amps NOTE For more information about the charger kindly refer the charger manufacturer s user manual which is supplied along with the machine Disposal of Batteries Old b...

Page 21: ...21 RootsScrub B6050 B6050C Dom Exp...

Page 22: ...crub B6050 B6050C Dom Exp Roots Multiclean Ltd R K G Industrial Estate Ganapathy Coimbatore 641 006 India Phone 91 422 4330 330 E mail rmclsales rootsemail com Web rootsmulticlean in Toll Free 1800 41...