RootsScrub B45 Series

BATTERY INSTRUCTIONS

Safety Symbols

Before using the machine

Battery charging procedure

The above instructions have been established for 
your safety and have to be strictly observed.

Ÿ

Observe  the  instruction  which  must  be 

mounted clearly at the charging point!

Ÿ

No Smoking!

Ÿ

No  naked  lights,  embers  or  sparks  in  the 

vicinity, risk of fire and explosion!

Ÿ

Wear protective goggles and protective

 clothing when working on the batteries!

Ÿ

Do not tilt the battery!

Ÿ

Only  use  certified  hoisting  and  transport 

equipment.

Ÿ

Keep children away from batteries.

Ÿ

Any splashes of acid in the eyes or on the 
skin must be rinsed throughly with plenty of 
clear pure water.

Ÿ

Then consult a doctor immediately!

Ÿ

Risk of fire explosion, avoid short circuits!

Ÿ

Caution! Metal components in the battery 

cells are always under voltage, never place 
any foreign items or tools on the battery!

Ÿ

Ensure the battery is in fully charged condition.

Ÿ

Check the battery electrolyte level, if required refill it.

- Drain both the tanks
- Move machine near charger location
- Switch Off Machine
- Tilt fresh tank.
- Connect charger to power supply.

Charge the batteries in a well ventilated area.

- Make sure to connect the charger to the specified 

voltage and frequency.

 - Ensure that the seat cover is completely open.
 - Do not place any objects on the battery.

 

Ÿ

Electrolyte is highly corrosive! 

Ÿ

Keep children away from batteries

Ÿ

Do not throw in garbage!

Traction Batteries (AGM/LA)

1. Initial Checking

Check the battery to ensure that it is in perfect mechanical 
condition. All screwed unions within the circuit must be 
tightened to ensure reliable contacts. Machine cables and 
charging cable are to be connected to the correct poles of 
the battery otherwise battery and charger can be 
damaged. 

2. Discharging

Ventilation openings may not be covered or closed. Electric 
connections (e.g-plugs) may be connected or disconnected 
only when the machine is in off condition. Discharge 
batteries must be recharged immediately and may not 
remain in discharged condition. this also applies to only 
partially discharged batteries.

The  battery  may  only  be  connected  up  to  the  allocated 
battery  charger  certified  for  the  particular  battery  size,  to 
avoid  overload  on  the  electric  current  Maintenance  Free 
Batteries have low gassing properties but are not completely 
free  of  gassing.  The  battery  is  to  be  connected  with  the 
correct  poles  (plus  to  plus  and  minus  to  minus)  to  the 
disconnected  battery  charger.  The  battery  charger  should 
then be switched on.

Summary of Contents for RootsScrub B4545

Page 1: ...sScrub B45 Series RootsScrub B4545 B4550 B4560 Walk Behind Floor Scrubber Drier Battery Read this manual completely and understand the instructionsbeforeoperatingthemachine EnglishVersion Owner s Manu...

Page 2: ...2 RootsScrub B45 Series...

Page 3: ...ion General Safety Instructions First Operation Operation Brush Operation Squeegee Procedure for Scrubbing Maintenance Battery Instructions 4 5 6 7 9 13 14 15 17 19 Roots Multiclean Ltd RMCL is not li...

Page 4: ...sold within India If the product requires repair or maintenance work to be performed please ensure that you get the machine serviced from an authorised service center or dealer of RMCL to ensurethatt...

Page 5: ...olic Squeegee Solenoid Valve B 4545 Disc Type with Parabolic Squeegee Solenoid Valve B 4545 Disc Type with Straight Squeegee B 4550 Disc Type with Straight Squeegee B 4560 Twin Disc Type with Straight...

Page 6: ...45 Dimensions L x W x H mm 1320 x 500 x 1130 1360 x 545 x 1140 1400 x720 x 1140 Total Weight Empty with battery kg 82 195 92 205 97 210 Total Weight ready to Operate kg 240 250 255 Description Units B...

Page 7: ...ures l Never vacuum up explosive liquids combustible explosive dusts as well as acids and solvents This includes diesel petrol kerosene paints paint thinners heating oil etc which can generate explosi...

Page 8: ...e sections Damaged parts may only be changedatanauthorizedservicecenter l It is not permitted to use aggressive and corrosive cleaningagents l Used batteries with the recycling symbol must not be disp...

Page 9: ...lyreduced Iffloorsareparticularlydirtyorifwaxhastobe removed basiccleaning thefloormustbetreatedtwice During the first cycle the floor is scrubbed with the cleaning agent selected according to the deg...

Page 10: ...ipmentandcause personalinjury LEGEND DESCRIPTION PURPOSE A Main Power Switch Initiates power supply to the system B Brush Motor Switch For On Off C Suction Turbine For On Off Shows information softwar...

Page 11: ...Suction Turbine ON A turbine symbol is displayed when thesuctionturbineisswitchedOn FIRST OPERATION Controls B4545x B4550x LEGEND DESCRIPTION PURPOSE A Main Power Switch Solenoid Initiates power suppl...

Page 12: ...The brush motor suction turbine icons will start flashingjustbeforethebatterycutofflevel 0016 10 8 Fully discharged condition 9 On Battery Charging Displays that the battery is in charging mode After...

Page 13: ...For B4545 B4550 Turn on switch B for a short time in ordertoallowlocking For B4545x B4550x Turn on switch C for a short time inordertoallowlocking When lowering the machine pay attention to prevent th...

Page 14: ...2 Mount the new sealing strips by inverse sequence of operation Removal of Squeegee 1 Squeegee 2 Squeegee Knob 3 Squeegee Bracket group Mounting of Squeegee first time Liftsqueegeebracketgroup 3 Mount...

Page 15: ...able for automatic machines low foaming in order to preclude damages at the suction turbine We recommend our agents for cleaning and care which are perfectly adoptedtothemachine How to operate the mac...

Page 16: ...ks Unclampthedrainhosefromthehoseclamp Lowerthetipofthedrainhosetothefloorlevel After draining the water completely clamp the hose in thehoseclamp After lowering the brush move the machine immediately...

Page 17: ...isposal which is ready to work and in good operatingcondition Please contact your local Roots Multiclean distributor the people there will be glad to perform that work for you There well trained perso...

Page 18: ...attery cable Tighten loose cable Main fuse blown Replace the fuse Main fuse blown Replace the fuse Faulty brush motor or loose cable Contact service Suction turbine does not work Faulty suction turbin...

Page 19: ...e sure to connect the charger to the specified voltageandfrequency Ensurethattheseatcoveriscompletelyopen Donotplaceanyobjectsonthebattery Electrolyte is highly corrosive Keep children away from batte...

Page 20: ...c gravity of the electrolyte and quantity shall be checkedweekly Ifthequantityislow refillwithbatterygradedistilledwater 5 Maintenance Daily maintenance Recharge the battery every time it has beendisc...

Page 21: ...of all regulations BATTERY INSTRUCTIONS Battery Specifications Type Lead Acid Volts 12V 96Ah No of batteries 2 per machine Charger Specifications Type On Board Rating 20 Amps Charger Specifications Ty...

Page 22: ...22 RootsScrub B45 Series...

Page 23: ...ootsScrub B45 Series Roots Multiclean Ltd R K G Industrial Estate Ganapathy Coimbatore 641 006 India Phone 91 422 4330 330 E mail rmclsales rootsemail com Web rootsmulticlean in Toll Free 1800 41 99 7...

Reviews: