ROOTECH ACCURA 2500 Quick Start Manual Download Page 10

Accura 2500M 

Setup Menu

※ Refer to the User Guide for details

*Required

Wiring *

DIP 

Ethernet

RS-485

Etc.

Swell 

Description

PT Primary Voltage[V] *

PT Secondary Voltage[V] *

Reference Primary

Voltage[V] *

AC/DC*

Custom

Summer Time

Local Time

A2550 LCD

MEASURMENT

EVENT

NETWORK

SYSTEM

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Voltage

Demand

Power

AC/DC

Voltage

Wiring

PT Primary Voltage [V]

Reference Voltage Mode

Reference Primary Voltage [V]

Min. Measured Secondary Voltage[V]

PT Secondary Voltage [V]

5

380

3P4W

380

Line to Line

380

000

AC

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Dip

Swell

PQ Curve

Volt. Connection

Dip

Dip Function

Dip Hysteresis [%]

Dip Threshold [%]

90.0

Disable

2.0

000

AC

Custorm

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Ethernet

RS-485

Etc.

Ethernet

IP Address

Gateway

Subnet mask

255.255.224.0

10.10.23.128

10.10.10.1

02:64:DA:6B:F5:D6

000

AC

MAC Address

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Ethernet

RS-485

Etc.

RS-485

Device Address

Parity

Baud Rate

9600

0

Even

1

000

AC

Stop Bit

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Ethernet

RS-485

Etc.

Etc.

Modbus TCP Timeout [sec]

Storm Control Mode

RSTP Mode

Disable

600

Enable

000

AC

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Dip

Swell

PQ Curve

Volt. Connection

Swell

Swell Function

Swell Hysteresis [%]

Swell Threshold [%]

110.0

Disable

2.0

000

AC

Custorm

PQ Curve 

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Dip

Swell

PQ Curve

Volt. Connection

Power Quality Curve

SEMI F47-0706

ITIC

IEC 61000-4-11/34 Class 3

Enable

Enable

Enable

000

AC

Custorm

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Description

Local Time

Summer time

NTP

A2550 LCD

Screen Selection

LCD Setup Exit Timeout [sec]

LCD Backlight Timeout [sec]

60

Auto Rotation

30

000

AC

LED

LCD/Buzzer

A2550 LCD

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Description

Local Time

Summer time

NTP

Summer Time

Mode

Start Month

Time Offset [min]

60

Start Nth Day of Month

2

Disable

March

Start Day of Week

Start Minute

120

Sunday

End Month

End Nth Day of Month

1

November

000

AC

LED

LCD/Buzzer

A2550 LCD

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Voltage

Demand

Power

AC/DC

Voltage

Wiring

PT Primary Voltage [V]

Reference Voltage Mode

Reference Primary Voltage [V]

Min. Measured Secondary Voltage[V]

PT Secondary Voltage [V]

5

380

3P4W

380

Line to Line

380

000

AC

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Voltage

Demand

Power

AC/DC

Voltage

Wiring

PT Primary Voltage [V]

Reference Voltage Mode

Reference Primary Voltage [V]

Min. Measured Secondary Voltage[V]

PT Secondary Voltage [V]

5

380

3P4W

380

Line to Line

380

000

AC

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Voltage

Demand

Power

AC/DC

Voltage

Wiring

PT Primary Voltage [V]

Reference Voltage Mode

Reference Primary Voltage [V]

Min. Measured Secondary Voltage[V]

PT Secondary Voltage [V]

5

380

3P4W

380

Line to Line

380

000

AC

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Voltage

Demand

Power

AC/DC

AC/DC

Mode

AC

000

AC

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Dip

Swell

PQ Curve

Volt. Connection

000

AC

Custom

Custom

Ch. Function

Module

Threshold

Category

Details

Time Delay

Edit

Reset

1

Over

Voltage

A

70 %

Main

3 sec

2

Over

Voltage

B

70 %

0,1P

3 sec

3

Off

Current

C

70 %

Main

3 sec

4

Off

Power

TOTAL

80 %

Main

1 sec

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Description

Local Tome

Summer Time

000

AC

Description

Device Name

Location

Installed Date

Description

Equipment#3-Load#1

Accura 2500

Room#1

2020 - 01 - 01

NTP

LED

LCD/Buzzer

A2550 LCD

EVENT

NETWORK

DEVICE

CONTROL

SYSTEM

MEASUREMENT

SETUP

INCOMING

ID 10

Description

Local Tome

Summer Time

000

AC

Local Time

YYYY-MM-DD

HH:MM:SS

Timezone Offset [min]

2021-03-15

17:16:06

540

NTP

LED

LCD/Buzzer

A2550 LCD

Summary of Contents for ACCURA 2500

Page 1: ...Accura 2500 2550 Quick Setup Guide AC Please refer to the User Guide for details...

Page 2: ...Accura 2500 2550 Setup Procedure Step 1 Step 2 Accura 2550CM Z Accura 2500...

Page 3: ...button to enter SETUP mode Short Press Button Long Press Accura 2550 Button Operation Makes menu item changeable blinking Move to the next menu item Change value Select the menu item to change Save th...

Page 4: ...ccura 2550CM Z Setup Menu Required ID Load Direction Load Mode Phase Sequence Rated Current CT Ratio CM 3P 5A module only Displays menu item in the following order when short pressing th SET button ID...

Page 5: ...annot exceed the base current value Rated Current Model Accura 2550CMZ 3P 630A 630A Accura 2550CMZ 3P 800A 800A Accura 2550CMZ 3P 400A 400A Accura 2550CM Z 3P 250A 250A Accura 2550CM Z 3P 125A 125A Ac...

Page 6: ...6000A Secondary Rated Current 5A then CT ratio 6000A 5A 1200 CT Ratio CM 3P 5A module only Phase Sequence Setup range Positive sequence L3 L1 L2 3 Ph LOAD Negative sequence L1 L3 L2 3 Ph LOAD Load Di...

Page 7: ...ID Rated Current Setup range 1 Base Current The value set by users cannot exceed the base current value Model Accura 2550CM Z 1P 125A 125A Accura 2550CM Z 1P 250A 250A Accura 2550CM Z 1P 100A 100A Acc...

Page 8: ...Accura 2550CM Z 1P Load Direction Setup range N L1 Left 1 Ph LOAD Setup range Select Line to Neutral N L1 1 Ph LOAD Select Line to Line L2 L1 1 Ph LOAD Right N L1 1 Ph LOAD Phase Selection...

Page 9: ...n Move to the measurement screen Move to the setup screen Move to the event screen Move to the previous screen Enter a setup value Cancel the entered value Apply the value ENTER CANCEL APPLY LCD touch...

Page 10: ...000 AC LED LCD Buzzer A2550 LCD EVENT NETWORK DEVICE CONTROL SYSTEM MEASUREMENT SETUP INCOMING ID 10 Description Local Time Summer time NTP Summer Time Mode Start Month Time Offset min 60 Start Nth Da...

Page 11: ...Setup range Accura 2500M Voltage Type Mode AC DC ENTER CANCEL Mode AC DC ENTER CANCEL AC Mode Default DC Mode Mode AC...

Page 12: ...Setup range Accura 2500M Wiring Three Phase 4 wire Default Three Phase 3 wire Single Phase 2 wire Single Phase 3 wire 3P3W 1P2W 1P3W Voltage Connection 3P4W 1P2W 1P3W 3P3W ENTER CANCEL Wiring 3P4W...

Page 13: ...ction Accura 2500M Wiring L1 L2 L3 N Fuse Fuse PTs Fuse Fuse PTs L1 L2 L3 Fuse Fuse PTs L1 L2 Ground Fuse Fuse PTs L1 Ground Three Phase 3 wire 2PT Connection Single Phase 3 wire 2PT Connection Single...

Page 14: ...ry Voltage PT Primary Voltage V PT Primary voltage rating PT Secondary Voltage V PT Secondary voltage rating Setup range Setup range 1 999 999 ex 1 999 ex 380 Default 380 Default PT Primary Voltage V...

Page 15: ...Accura 2500M Reference Primary Voltage Reference Primary Voltage V Setup range 1 999 999 ex 380 Default Reference Primary Voltage V 380...

Page 16: ...Please refer to the User Guide for details...

Reviews: