Accura 2350 Module ID Setup
Module ID Update
Module ID Status
cn[Communication]
1,4
Number of communicable IDs(automatic recognition)
cF[Conflict]
2,4
Number of confilct/standby IDs(automatic recognition)
to[Total]
3,4
Total number of Module IDs (automatic recognition)
Update of Communicable Module ID Information for module management
IduP[ID Update]
5
Long Press Left button to update module ID information
1. cn[Communication]: Accura 2300 communicates with Accura 2350 in real time using communicable module ID
information.
2. cF[Conflict]: Number of Accura 2350 modules with duplicate ID[ID collision] or Standby ID. These Accura 2350s cannot
communicate with Accura 2300.
3. to[Total]: Number of Accura 2350 modules that are physically connected.
4. When Accura 2300 and 2350 are physically connected, they are automatically recognized and displayed.
5. Execute ID update after resolving cF[Conflict] module. If there is a change in the connected module after this, in the
display mode, this is indicated by blinking UNIT segment on the upper left.
Module ID
ID
Description
Communication ID
ID 0 - 39
Able to communicate with Accura 2300.
Conflict ID
ID Duplication Two or more IDs are the same Module ID, unable to communicate.
Standby ID
6
ID 255
Module ID for connection status recognition, unable to communicate.
6. All Accura 2350s are factory-assigned as standby IDs by default.
Note
cF number is nonzero and blinks[Two or more Accura 2350s with duplicate IDs are recognized, or Accura 2350 modules
with Standby IDs exist].
①
Assign conflict IDs of Accura 2350 with another communicable ID.
②
After eliminating all collisions , execute
IduP
[Id Update] to update again the information of communicable
Accura 2350s.
Module ID Auto Assignment
The communicable Module ID
1
of Accura 2350 can be automatically assigned in the following 4 ways.
Setup range
RJ-1 Inc2
Module ID is increased by 2 from RJ-1.
Refer to page 156.
RJ-1 Inc2
Module ID is increased by 2 from RJ-2.
Refer to page 156.
RJ-1 Inc1
Module ID is increased by 1 from RJ-1.
Refer to page 157.
RJ-1 Inc1
Module ID is increased by 1 from RJ-2.
Refer to page 157.
StbY
All modules are initialized to standby ID.
Refer to page 158.