Rontan IS2100-M Generation 2 Installation And Operator'S Manual Download Page 9

IS2100-M Generation 2 

 Installation, Program & Operation Manual 

 

www.rontan.com.br

 

REV 1 

Page

 

11.10 

– Function Hands Free 

 
The  IS2100-M  G-II  has  a  feature  called  "Hands  Free",  which  allows  the  user  to  change  the  siren 
tones  using  the  steering  wheel  horn  switch.  This  function  is  activated  whenever  any  siren  tone  is 
turned on, except the tone "Man" and "Horn". 
 
When  the  hands-free  function  is  active,  the  internal  relay  is  activated  by  disconnecting  the  vehicle 
horn. The sequence of tones changed by the flywheel continues the table 6  
 

Notes

 

* As soon as the Hands-free function is active, the vehicle horn does not work. 
* The steering switch signal can be either positive (12V) or negative (GND), depending on the vehicle. 
Pin  1  of  the  10  pin  connector  (input  1)  must  be  energized  in  accordance  with  this  polarity.  If  the 
steering signal is positive, pin 1 should be connected to 12V or stay loose. If the signal is negative, 
pin 1 should be connected to GND, as shown in figures 6 and 7. 
 
To  turn  off  the  siren  tones  you  must  press  the  flywheel  by  2  seconds.  To  disable  the  Hands-free 
function, press the key of the siren tone that is active. 

 

11.10.1 

– Diagram of the basic Hands Free function

 

 

 

 

 

 

 

Figure 6: Connection with Input 1 in +12V     Figure 7: Connection with Input 1 in in GND 

 

Sequence 

Siren Tone 

WAIL 

YELP 

HI-LO 

PIERCE 

Goes back to sequence #1 

Table 6: Sequence of siren tone

 

12 

– Digital Output 

 
The  8  digital  outputs  of  250  mA  of  the  IS2100-M  G-II  have  protection  against  short-circuits,  by 
monitoring the current at the time that the outputs are activated. If the current exceeds the 250 mA at 
the time that the output is turned on, it will be active as well for more than 25 ms, when doing a new 
monitoring of current. If at this moment if the current is below 250mA, will be considered normal (the 
load  is  capacitive),  but  if  after  this  time  if  the  continuous  output  current  greater  than  250  mA,  all 
outputs  will be disabled and an error message  will be indicated in the LEDs on the microphone,  as 
indicated in the figure 8 and the data in table 7.

 

 

Summary of Contents for IS2100-M Generation 2

Page 1: ...ons for routing traffic and or possibly any error code in the system External fuse Eight outputs of 250mA Input for pos power ignition Input to activate the backlight of the panel backlight Input to enable I Saver turn off after 4 hours Digital serial communication with the products of the Rontan Series S and wide E Tech Battery management system Digital regulation of the audio volume for the radi...

Page 2: ... DO NOT drill any holes into this device If it s necessary to perform a battery charge with an auxiliary car battery it s highly recommended to disconnect the power supply of this product to avoid a voltage surge that may damage it and the electrical system of the vehicle DO NOT jumpstart the vehicle with the battery connected to the siren and light bar system Auxiliary lights and sirens are inten...

Page 3: ...en tone HI LO and Hands Free function Second Function Pressing the button for more than 1 second the microphone audio level refer to page 7 or of the Radio refer to page 9 or the intensity of the l backlight refer to page 8 increases YELP Activates the siren tone YELP and Hands Free function PIERCE Activates the siren tone PIERCE and Hands Free function Second Fuction Pressing the button for more ...

Page 4: ...al Inputs 1 Selection of the polarity of the Steering Wheel signal 2 Activates the lightbar in mode SL3 3 Activates the siren mode MAN 1 4 N A 5 Activates the function I Saver 6 Activates the light panel and the Dimmer function 7 Deactivates the Siren tones 8 Input for the command Pos Power 9 Radio Inputs 10 Digital Outputs 1 Activated by the buttons 1 2 and 3 2 Activated by the buttons 2 and 3 3 ...

Page 5: ...ce compatible with all Rontan S Series lightbars It also has analog signal outputs to command third party lightbars 8 Installation The installation of this equipment requires that the installer has a good knowledge of automotive procedures and electrical systems Before starting the installation on your device it is important to read these instructions for the safe correct installation and operatio...

Page 6: ... com br REV 1 Page 6 A fuse must be installed on the end of the harness cable Figure 3 in order to prevent problems in the vehicle electrical system because of short circuits Figure 3 Harness Cable Connectors 10 Electrical Wiring Diagram Figure 4 Electrical Wiring Diagram ...

Page 7: ... this input to a Vbat the mode SL3 is activated on the lightbar 11 4 Siren Tone Air Horn Input 3 When you connect this input to a Vbat the IS2100 G M II activates the Air Horn in the siren 11 5 I Saver Input 5 Input configuration of the I Saver See the description of the Ignition Input on page 9 11 6 Backlight Panel Illumination Input 6 The backlight input should be connected to the power source o...

Page 8: ...d may be always connected shutting down together with the signal or trigger off only about 4 hours after the trigger signal INPUT I SAVER INPUT IGNICIÓN Behavior BAT Disconnecting from BAT Wait 4 hours and then turn off mode I Saver GND Disconnecting from BAT IS2100 M G II count 1 s and then go to mode stand by Open Disconnecting from BAT IS2100 M G II does not turn on Any way BAT IS2100 M G II on...

Page 9: ...ld be connected to GND as shown in figures 6 and 7 To turn off the siren tones you must press the flywheel by 2 seconds To disable the Hands free function press the key of the siren tone that is active 11 10 1 Diagram of the basic Hands Free function Figure 6 Connection with Input 1 in 12V Figure 7 Connection with Input 1 in in GND Sequence Siren Tone 1 WAIL 2 YELP 3 HI LO 4 PIERCE 5 Goes back to ...

Page 10: ...ike that for 10 seconds the LED lights up If the battery voltage stays well for more than 20 seconds like this the exit 7 Low Bat will be activated Figure 9 Low Battery LED indicator IMPORTANT If it becomes necessary to enable the functions of the IS2100 M G II even if the battery voltage is low the user can press any key you want and the IS2100 M G II will run the function normally except the sir...

Page 11: ...neration 2 Installation Program Operation Manual www rontan com br REV 1 Page 11 13 Installation and Dimensions Figure 10 External dimensions of the IS2100 M G II Figure 11 Microphone Figure 12 Microphone Support ...

Page 12: ...emote Control Check that the connections Short Circuit on the 0 25A outputs Check the connections on the 8 digital outputs Short circuit n the siren output or overheating Check the siren speaker and connections Invalid instruction or invalid commands Check the IS2100 M G II programming No synchronization between the CPU and the lightbar Check the connections with the lightbar Low battery Voltage T...