4.3

Installation announcements

Please follow the security regulations strictly when installation, operate everything carefully

in case of any equipment damage or human injury.

Notice

】:

This equipment should be installed by RONDS application engineers or other

people with professional training.

Danger

】:

Please make sure the security when using 220V power supply in case of any

human injury.

Danger

】:

When install sensors on the surface of the machine, please make sure the

machine is stopped.

4.4

Installation

4.4.1

RH560 Installation

a.

Fixing method

RH560 has two methods of fixing: Hanging and fixation though holder. Users can choose one

of them according to the actual situation.

The following is the hanging fixing sketch, it can be fixed on the wall or other planar

structure.

Notice

】:

the height RH560 should be more than 1.6 meterS against the floor.

Notice

】:

Choose the area which has strong signal strength of your mobile phone as the

installation position.

Fixation though holder

Summary of Contents for RH560-4G

Page 1: ...第 1 页 共 17 页 Wireless Machinery Monitoring Station RH560 4G User Manual Anhui Ronds Science Technology Incorporated Company 2016 03 ...

Page 2: ...H560 Installation 8 4 4 2 RH505 Installation 9 4 4 3 RH509 Installation 9 4 5 Announcement for the first time using 10 5 Equipment operating 10 5 1 Summarize 10 5 2 Announcements 10 5 3 RH560 Switch and LED description 10 5 4 RH505 Switch and LED description 11 5 5 RH505 Change battery 11 5 6 RH509 Switch and LED description 12 5 7 RH509 Change battery 12 6 Software user manual 12 6 1 Summarize 12...

Page 3: ...oper operating Danger Means serious equipment accident or human injury might be occurred if there is improper operating 2 Product introduction 2 1 Summarize RH560 WIRELESS CMS is positioned on industrial enterprises which is developed by RONDS Company for scattered measuring points and unavailable wiring work It integrates vibration temperature and speed signals System hardware includes RH560 wire...

Page 4: ...ort for multiple DAQ parameter sending 2 Wireless collection station will update the DAQ parameter after receiving from MOS3000 software 3 RH505 and RH509 sensor will receive DAQ parameters after power on and then collect data accordingly these data shall be sent to RH560 wireless collection station through Zigbee 4 RH560 wireless collection station receives data from every wireless sensor and upl...

Page 5: ...be never so easy communication type 3G 4G realize monitoring of both constant and variable speed rotating machines Low consumption design IP66 protection degree EXIA intrinsic safety certified can be sued for special industries like petrochemical and mining field Internal antenna more reliable in industrial field 2 5 Technical specifications ...

Page 6: ...quency Range 3dB 2 15kHz Temperature Measurement Parameter Temperature Range 40 125 Temperature Accuracy 1 40 125 Electrical and Structure Parameter Power Supply Lithium thionyl chloride battery 3 6V 3 3Ah Communication Method 2 4GHz IEEE 802 15 4 Dimension 46 mm 94 mm Diameter Height Weight 188 g Environment Parameter Working Temperature 40 70 IP grade IP67 RH509 Wireless Speed Sensor Performance...

Page 7: ...ducts and connect power supply Make sure there is earth wiring for power supply and check the reliability Please contact with RONDS if any problems Notice Please contact RONDS company if any questions or suggestions 4 Installation 4 1 Summarize This online monitoring system is consists of several accessories in order to reach the best working status please read this manual carefully before install...

Page 8: ...njury Danger When install sensors on the surface of the machine please make sure the machine is stopped 4 4 Installation 4 4 1 RH560 Installation a Fixing method RH560 has two methods of fixing Hanging and fixation though holder Users can choose one of them according to the actual situation The following is the hanging fixing sketch it can be fixed on the wall or other planar structure Notice the ...

Page 9: ...505 Installation RH505 is fixed through M6 screw and magnet base on the surface of machines the torque of RH505 is 8N Notice Before install the magnet base please clean the measuring point position greasy dirt or dust is not allowed Notice RH505 should be fixed after the glue is solidified completely Notice The cover of RH505 should be fixed well Warning If the installation is improper it will cau...

Page 10: ... order to ensure safe correct and efficient using of this equipment please read this manual carefully before operating 5 2 Announcements After installation and configuration please pay attention to the following Check the connection of power supply and earth wiring Check each component parameter setting Check the equipment fixing Make sure the working environment is suitable for the equipment Warn...

Page 11: ...ica tors Status Description LED green light light for 3 seconds flicker once off Normal connection with RH560 light for 3 seconds off Fail to communicate with RH560 Light all the time Configuration mode Quick flicker once RMS collection Quick flicker twice Upload data to RH560 All of RH505 under one RH560 light at the same time Synchronously data collection 5 5 RH505 Change battery The battery of ...

Page 12: ...cked from Online Server of server the battery have be to changed when the voltage is lower than 2 8V Warning Make sure the machine is stopped before change battery Warning Pay attention on the battery negative and positive pole Notice Fix the black cover well after battery changed 6 Software user manual 6 1 Summarize The wireless monitoring system should be used together with RONDSMOS3000 online m...

Page 13: ...re MOS3000 System configuration tool and Online service is started before login there should be a tick mark 6 3 Software configuration 1 Choose System configuration right click Root to create Organization Machine Measuring point and DAQ definition The information of Organization Machine and Measuring point can be edited RH560 system support for 3 measurement definition maximally data length and Fm...

Page 14: ...er name choose the right database to store data or create new database in the popup windows 3 Collection station code input the last four number 4 Collection method variable speed or constant speed test mode is forbidden 5 Monitoring machine click it to add relative machines 6 Associate measuring point ...

Page 15: ...se refer to MOS3000 Online monitoring software user manual 6 5 Software abnormal processing 1 Can t login software a please check the SQL database and local server is working normally or not b Please check the online service and configuration service is started or not 2 Failed to send DAQ definition Please check if the data collector is displayed in the online service 3 No collected data display S...

Page 16: ... technical department of RONDS company Fault type Possible reason solution RH560 RUN LED is not light Power disconnected or switched off Check power supply and switch Normal communication but now data collector displayed in online service RH560 or server IP setting is not associated with each other Check configuration info All sensors have no data 据 RH560 disconnected with server Check RH560 power...

Page 17: ...try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Ope...

Reviews: