![Ronde & Schwarz 1304.0004.03 User Manual Download Page 626](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004-03/1304-0004-03_user-manual_1484985626.webp)
Remote Commands
R&S
®
FPL1000
626
User Manual 1178.3370.02 ─ 09
//Set marker to maximum in IQ1 and query result
CALCulate:MARKer:MAXimum
CALC:MARK:Y?
//Switch to second IQ channel and retrieve results
INST:SEL 'IQ 2';*WAI
CALCulate:MARKer:MIN
CALC:MARK:Y?
//Switch to first Spectrum channel
INST:SEL 'Spectrum';*WAI
//Query one of the SEM results
CALCulate:MARKer:FUNCtion:POWer:RESult? CPOWer
//Switch to second Spectrum channel
INST:SEL 'Spectrum 2';*WAI
//Query channel power result
CALCulate:MARKer:FUNCtion:POWer:RESult? ACPower
11.6
Configuring and Performing Measurements
The following commands are required to configure measurements in a remote environ-
ment. The tasks for manual operation are described in
....................................................................................626
Configuring Power Measurements
........................................................................630
............................................................................ 634
Measuring the Channel Power and ACLR
............................................................ 638
Measuring the Carrier-to-Noise Ratio
................................................................... 656
Measuring the Occupied Bandwidth
..................................................................... 657
Measuring the Spectrum Emission Mask
..............................................................659
.............................................................................688
Analyzing Statistics (APD, CCDF)
........................................................................ 701
Measuring the Time Domain Power
...................................................................... 711
Measuring the Harmonic Distortion
.......................................................................720
Measuring the Third Order Intercept Point
............................................................724
Measuring the AM Modulation Depth
....................................................................727
Remote Commands for EMI Measurements
.........................................................729
.................................................................................. 742
Programming Example: Performing a Basic Frequency Sweep
........................... 747
11.6.1
Performing Measurements
Useful commands for performing measurements described elsewhere
●
●