Document:
Version: 1.0 Creator: 5166 Validator: 5160
April 2017
General Instructions
Removing the setting stem can only
be effected in Pos. I.
The use of supporting screws is es-
sential when mounting the hands.
Permitted hand setting strengths:
Hr / min. hands:
<40N
Second hand:
<30N
During quick date correction (set-
ting stem in position II), a date swit-
ching speed of 5 d/s must not be
exceeded.
The following lube points have to
be added for the assembling of new
winding stems:
T2-Instructions
225e
R 150
Fitting dial and hands
• Crown in position III
• Wind hour hand forwards, until date changes
• Remove working hand
• Set friction spring 3315.003 on the hour wheel
• Fit dial
• Point all hands towards 12o‘clock
• Set time
• Crown in position II
• Set date
• Crown in position I
Date switching duration:
~1½h
Nbr. of crown windings in pos. I to wind it up fully:
<30Turns
Movement holder
Setting hands
H R150.1A
Movement holder
Removing setting stem
H R150.1T
HP 1300