background image

Technical Instructions   7004.N

Electrical checking

16 Mar 2010

7

Voltage of battery

1.50 - 1.55 V

Battery test

Battery must be removed from movement

Consumption (M1) of movem. (Pos. I)

1.20 - 3.1 µA

Supply power from measurement equipment (1,55 V)

Consumption (M1) of movem. (Pos. III)

0.1 - 0.3 µA

Supply power from measurement equipment (1,55 V)

Lowest voltage for movement (M1)

less than 1.3V

Lower limit for operation of movement

Adjust voltage on the measuring eqipement to 1.55 V. The slowly reduce the
tension untill the movement stops

Accuracy (seconds / month)

-10/+20 s/M

Check for a time of minimal 60 seconds

Resistance of the coil: motor 1 (movem.)

1.5 - 1.7 kOhm

Ref. 3621.053.RK

The resistance of the coil can be measured on the electronics.

Summary of Contents for 7004.N

Page 1: ...age Nr 381 1 5V Autonomy theoretical 48 months Instantaneous rate 25 C 10 20 sec month Current cons typ 1 43µA date mechanisme not in gear Current cons max 3 1µA Torque sec 10µNm typ Torque minute 500µNm typ Operating temperature 0 C 50 C Resist to magn fields 18 8 Oe 1500 A m Resistance to shock NIHS 91 10 functions Position I crown Neutral Position II crown Setting the date quick mode Position I...

Page 2: ...nd the mechanism is already placed on the backside place the stem into the middle position Then use 1 screw 4000 249 to fix the lever for setting lever 4000 249 Screw 9 3016 027 Stop lever 10 Position the Stop lever under the Lever for setting lever and fix the Stop lever by using 1 screw 4000 249 The reset arm of the Stop lever must be placed according to the picture Use Moebius 8200 at the conta...

Page 3: ...1 9014 000 Moebius 9014 22 3603 080 Battery insulator 23 3601 120 G Battery clamp 24 Use 1 screw 4000 248 4000 248 Screw 25 3503 071 Tube 26 2 pieces D 3612 196 Electronic module small second 27 The coil is integrated into the electronic module Use 5 screws 4000 250 4000 250 Screws 28 3603 081 Spacer 29 2130 183 G Electronic module cover 30 Use 4 screws 4000 244 3600 032 Battery 31 Use a plastic t...

Page 4: ...or setting wheel 38 Use Moebius 8200 on both setting wheels 3015 078 CO Rocking bar 3 positions 39 Moebius 8200 greace must be placed between both levers oiling wheel with Moebius 9020 G 2130 194 Setting mechanism cover 40 Use 4 screws 4000 305 4000 305 4 Screws 41 3000 194 CO Stem 42 Prior to the insertion of the stem some greace must be placed on the square part of the stem 3004 204 Intermediate...

Page 5: ...heel 55 Oil must be placed at the pins before inserting the wheel 3147 061 Intermediate date wheel 56 3404 006 CO Day cam 12h 57 3406 032 Day rack 58 Moebius 8200 must be placed between cam and rack Orientation of the parts like indicated 3406 031 Day rack lever 59 3507 059 CO Date corrector wheel 60 J 2130 191 Date indicator plate 12h 61 3905 068 Date corrector spring 62 Use 1 screw 4000 244 3905...

Page 6: ...cator can be minimized L 3004 212 Days driving wheel 72 Insert this wheel and assure its bended down arm is properly inserted into the counterpart on then Day finger Make sure that during insertion of this wheel the Day finger is in contact with the day cam This can be done by slightly turning this wheel counter clock wise while inserting 3401 082 FI Day indicator pinion 73 3147 062 Tens intermedi...

Page 7: ...m Pos III 0 1 0 3 µA Supply power from measurement equipment 1 55 V Lowest voltage for movement M1 less than 1 3V Lower limit for operation of movement Adjust voltage on the measuring eqipement to 1 55 V The slowly reduce the tension untill the movement stops Accuracy seconds month 10 20 s M Check for a time of minimal 60 seconds Resistance of the coil motor 1 movem 1 5 1 7 kOhm Ref 3621 053 RK Th...

Page 8: ...Mar 2010 8 Coil insulation motor 1 M1 kOhm indefinite high The resistance between each coil and pole must be measured Accelerated test of movement M1 1 55 V 8 steps sec To activate this test mode the corresponding test point must be connected to the Pole ...

Reviews: