Summary of Contents for BP-1000

Page 1: ...USER MANUAL Fully Automatic Blood Pressure Meter BP 1000 ...

Page 2: ... Battery Installation 6 F Time Adjustment 7 G Erase Memories 8 H About the Touch Key 8 I Applying the Cuff 9 J Measurement Procedure 10 K Take a Measurement 11 L Recalling Memories 12 M Troubleshooting 13 N Maintenance 14 Q Explanation of Symbols on Unit 15 R Electromagnetic Compatibility Information 16 ...

Page 3: ... x 13 5cm normal cuff Operating Condition 10 C 40 C 30 RH 80 RH Storage Condition 5 C 35 30 RH 80 RH Power Supply 4 x AA batteries Dimensions Approx 150 L x 110 W x 65 H mm Weight Approx 370g not including batteries Display LCD backlit Touch pad key Set clock key ON OFF key Memory key Memory 99 measurements Can display the average of the last 2 measurements 1 ...

Page 4: ...humidity and direct sunlight Avoid dropping or strongly shocking the main unit and protect it from dust 5 Leaking batteries can damage the device Remove the batteries when the device is not used for a long time 6 Do not activate the device when the cuff is not connected or the cuff is not wrapped on your arm 7 Do not disassemble the monitor or cuff do not wash the cuff 8 If the device is stored in...

Page 5: ...Your Blood Pressure Among the various health problems today problems associated with high blood pressure are very common High blood pressure s dangerously strong correlation with cardiovascular diseases has made measuring blood pressure become more important than ever Blood Pressure Classification Chart The World Health Organization WHO has developed a blood pressure standard according to which ar...

Page 6: ... well as the point at which you will be considered at risk Blood Pressure Fluctuation Blood pressure fluctuates all the time You should not be worried if you get two or three measurements at high levels Blood pressure changes over the month and even throughout the day It is also influenced by season and temperature personal condition etc 4 ...

Page 7: ...D Parts identification 1 Systolic Pressure 2 Diastolic Pressure 3 Pulse Rate 4 Time and date 5 Heart Rate Indicator 6 Low Battery Indicator 7 Memory Number 5 ...

Page 8: ...lose the battery compartment Do not mix old and new batteries 4 You need to replace the batteries when 1 The low battery icon appears on display will not appear when battery is full 2 Press the key but nothing appears on the display Caution 1 Battery life varies with the temperature and may be shorter at low temperatures 2 Batteries are hazardous waste Do not dispose of them together with the hous...

Page 9: ...adjust the day Press the key to get the desired day 4 Press the key the display will show a blinking number showing the hour minute operate according to step 3 to get the desired time 5 Press key during the time adjustment procedure to stop the time adjusting process directly The adjustment result will be saved Note Time adjustment only works in the Power Off status Please switch the device to the...

Page 10: ...asurement results 3 Press the key to get back to Stand By status H About the Touch Key When installing the battery don t touch the key pad The screen will display and then it will go out later When you turn on the device by using the touch keys you should press the touch key for 1 2 seconds continuously If the touch key doesn t work properly please move away your finger wait for 4 10 seconds it wo...

Page 11: ... 3cm above the elbow 4 Adjust your cuff s air tube the air tube shall lie over the brachial artery on the inside of the arm The tube should run down the centre of the arm 5 Tighten the cuff by pulling the Index end of the cuff Note The PROPER FIT RANGE If the Index arrowhead falls within the PROPER FIT RANGE it indicates that this cuff is suitable for you If the Index arrowhead falls out of the PR...

Page 12: ... minutes before taking the measurement Try to measure your blood pressure at the same time every day Note During measurement do not be alarmed if you feel that the cuff is very tight An individual s blood pressure varies constantly depending on the time of the day and what you have eaten What you drink can have a very strong and rapid effect on your blood pressure This device measures blood pressu...

Page 13: ...arts to deflate when the heartbeat was detected a heart symbol will blinking on the display The blinking mark blinks with each heartbeat 4 When the measurement is completed the cuff will deflate automatically Systolic diastolic and pulse with date time will be shown simultaneously on the LCD screen The measurement results will be stored automatically If a mistake was detected during the measuremen...

Page 14: ...to memory recall function 2 After press the key a symbol will displayed The average systolic diastolic and pulse of the last 2 measurements will display Note The symbol means average 3 Pressing the key again to get the latest results By pressing the key to get the desired measurement results 4 Hold the key the memory number will increase quickly release the key to get the desired measurement resul...

Page 15: ...e measurement The cuff position is not correct Sit comfortably and still Raise your hand so that the cuff is at the same level as your heart If you have a very weak or irregular heartbeat the device may have difficulty in determining your blood pressure Measurement values appear too high or too low Blood pressure varies constantly Many factors including stress time of day and how you wrap the cuff...

Page 16: ...ble this monitor 5 If you do not use the monitor for a long time please remove the batteries 6 If the monitor becomes dirty please clear it with a soft dry cloth Do not use any abrasive or volatile cleaners 7 No component inside the monitor can be maintained by user 8 After open the packing the environmental conditions for transport and storage a Temperature and Relative humidity 20 C without rela...

Page 17: ...plied part Serial number Batch code Catalogue number CE Mark Date of manufacture Manufacturer Keep dry Keep away from sunlight Temperature limit Collect separately from other household waste Refer to user manual Consult instructions for use Caution 15 ...

Page 18: ... S DECLARATION ELECTROMAGNETIC IMMUNITY The Romed Automatic Digital Blood Pressure Monitor is intended for use in the electromagnetic environment specified below The customer or the user of The Romed Automatic Digital Blood Pressure Monitor should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic dis...

Page 19: ...form fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic is affected by absorption and refle...

Page 20: ... maximum output power of the communications equipment Rated maximum output of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meter...

Reviews: