INSTALLATION INSTRUCTIONS 

 

 
The R-1000 Command center includes four components: The keypad, temperature probe 
and the power unit. 
 

INSTALLATION OF THE POWER UNIT 

  
The power unit is equipped with brackets, allowing it to be attached onto a surface. 
Locate the power unit, in an upright position with the wires coming out of the bottom, as 
close to the steam unit as possible.

 

(See

 

attached wiring diagram) 

 

NOTE: 

 

Cables for the keypad and thermostat are 25 feet in length and can not be 

extended. It is essential that the power unit be located no further than 25 feet away 
from the shower. 

 

INSTALLATION OF THE KEYPAD 

 

The keypad should be recessed into an inside wall of the shower in an area easily reached 
by the user. 
 
(1) Set a 4’x 4’ 2 gang box midway up the shower wall to accommodate the control. 
  
(2) Attach the keypad to the 2 gang box with the 4 screws provided. 
 
 

NOTE:  Make sure that the keypad cable is securely plugged in before attaching to 

the gang box. (See fig. 2)  
 

INSTALLATION OF THE TEMPERTURE PROBE 
 

The temperature probe should be located approximately 6 inches from the ceiling in the 
wall furthest from the shower door. 
 
(1) Using a 5/16” drill bit, drill a hole through the tile surface to accommodate the probe. 
(2) Slide the probe through the hole allowing the entire metal tip to protrude into the 
shower area.        
(3) Once the probe is through the hole, grout the hole closed around the cable. 
 

NOTE: 

   

It is important that the metal tip stick straight out away from and not 

touch the surface of the wall. If the metal tip is touching the wall, the sensing device 
will receive a false reading and will not be able to accurately sense the temperature 
inside the room. 

 
 
 

 

 

 

 

 

 

 

 

 

Page 2 